Product Documentation
Abstract
Informix server provides periodic fixes for release 11.70. The information below lists the known customer-reported defects in Version 11.70.xC7. This report combines both Windows- and UNIX-specific defects.
Content
| Fix release date: 4 December 2012 Last modified: 7 December 2012 Status: Recommended | |
APAR | Description |
| IC69419 | FRACTION OF SECOND IN GL_DATETIME %F DID NOT DISPLAY AS EXPECTED |
| IC72617 | IFXCOLLECT DOES NOT WORK ON WINDOWS SYSTEMS. |
| IC78379 | [WINDOWS] USER INFORMIX AND GROUP INFORMIX-ADMIN EXIST AFTER CUSTOM INSTALL SPECIFYING LOCAL SYSTEM ACCOUNT |
| IC81344 | MIXING UP A NON GL_USEGLU SERVER WITH A GL_USEGLU DATABASE SHOULD GIVE A MEANINGFUL ERROR MESSAGE INSTEAD OF -211/-103 |
| IC81491 | DBSCHEMA USED REMOTELY BETWEEN 11.70 AND 11.50 DATABASE INSTANCES WILL FAIL WITH ERRORS |
| IC81763 | INSTALLER REFUSES TO PUT DEMO SERVER TO NFS MOUNTED STORAGE |
| IC81813 | -535 ALREADY IN TRANSACTION WHEN EXECUTING A SPL PROCEDURE THAT CONTAINS A BEGIN WORK STATEMENT FROM A DRDA CLIENT |
| IC81894 | ONMONITOR PRODUCES 25582 ERROR ON EXIT |
| IC82486 | USING INCORRECT DBONPLOAD SETTING DURING MIGRATION CAN LEAD TO AF AND ABORTED CONVERSION |
| IC82507 | ONPLADM MIGHT FAIL WITH GENERIC ERROR MESSAGE IF REQUIRED DBONPLOAD VALUE DIFFERS FROM ITS VALUE DURING ENGINE STARTUP |
| IC83706 | CONFUSING NUMBERS IN COLUMN QUEUE IN CDR LIST SERV OUTPUT |
| IC83985 | FUNCTIONALITY AND DESCRIPTION OF SYSTEM VALUES IN IFXDEPLOY.CONF FILE IS UNCLEAR |
| IC84823 | ONMODE -P -1 JVP STILL CRASHES THE DATABASE SERVER WHEN JVPARGS IS SET |
| IC85085 | RUNNING UPDATE STATISTICS ON A TABLE WITH FRAGMENT LEVEL STATS RETURNS AN INCORRECT MESSAGE RELATED TO SBSPACENAME |
| IC85171 | SYSADMIN:ALERTCLEANUP FUNCTION MUST BE RECREATED DURING MIGRATION/CONVERSION |
| IC85330 | SEQUENTIAL SCAN OCCURS WHEN RUNNING SELECT COUNT(*) ON LARGE TABLE WITH INDEXED COLUMN |
| IC85487 | CDR_SERIAL DOES NOT WORK PROPERLY IF YOU ADD A BIG NUMBER BEFORE |
| IC85696 | ASSERT WARNING: (PART <= SPTR->NUM_LPARTS) POSSIBLE DURING QUERY EXECUTION |
| IC85935 | MESSAGE FAILPOINT: 14100 IN LOAD JOB LOG FILE WHEN LOADING FROM EMPTY FILE AND TABLE CONTAINS LVARCHAR |
| IC86079 | ALTER TABLE VIA IFX_GRID_CONNECT RESULTS IN ERROR 19995 WHEN REPLICATE IS NOT HAVING PARTICIPANTS ON ALL GRID NODES |
| IC86189 | REMOTE SUB-QUERY HAS INCORRECT QUERY PATH WITH VERY LOW PERFORMANCE |
| IC86237 | RPM OPTION OF INSTALLER (IDS_INSTALL) FAILING WITH ARCHITECTURE IS NOT INCLUDED ON LINUX 32BIT |
| IC86443 | SELECT WITH WHERE CLAUSE CONTAINING MATCHES CONDITION WITH MULTIPLE WILDCARDS RETURNS WRONG RESULTS WITH CUSTOMIZED LOCALE |
| IC86490 | SUPPLIED KRAKATOA HAS OUTDATED TZ INFO |
| IC86493 | MISLEADING ERROR MESSAGE, UNEXPECTED RSS AUTHENTICATION FAILURE WHEN HA_ALIAS IS NOT SET |
| IC86641 | ASSERTION FAILURES DURING ROLL FORWARD OF RTREE LOG RECORDS AFTER RESTARTING LOGICAL RECOVERY DURING ARCHIVE RESTORE |
| IC86642 | WITH PDQPRIORITY SET, THREADS SHOULD NOT BE LEFT IN A AWAIT_MC STATE AFTER STORED PROCEDURE COMPLETION |
| IC86671 | DATABASE CANNOT BE DROPPED DUE TO MISSING SYSTEM CATALOG TABLE IF IT WAS UNLOADED ON V11.50 AND LOADED INTO V11.70 |
| IC86784 | AN ASSERT FAILURE IN INIT_TERM_PER_VALUE IS POSSIBLE WHEN MULTI INDEX SCAN IS USED |
| IC86785 | BTS INDEX CREATION ON SAME TABLE MUCH SLOWER THAN ETX INDEX |
| IC86822 | OPTIMIZER PREFERS INDEX PATH OVER SKIP SCAN WHICH RESULTS IN LONGER EXECUTION TIME |
| IC86952 | POSSIBILITY OF ERKEY (IFX_ERKEY_2 COLUMN) CORRUPTION |
| IC86978 | IWA: CREATING A DATAMART WITH DANISH LOCALE AND DANISH CHARS IN OBJECT RETURNS AQT10205I |
| IC86979 | INFORMIX SERVER SENT THE RESULTSET TWICE TO THE ODBC CLIENT IF THE DATABASE IS IN UNICODE |
| IC86993 | CDR CHECK REPLICATESET IFX_INTERNAL_SET RETURNS SQL FAILURE 195 WHEN THERE IS NETWORK DELAY BETWEEN SOURCE AND TARGET |
| IC86995 | ALTER TABLE ADD ERKEY IS SLOW WHEN TABLE HAS FOREST OF TREES (FOT) INDEX |
| IC87059 | EXECUTE PROCEDURE FAILED WITH 211/111 CANNOT READ SYSTEM CATALOG (SYSPROCBODY) AFTER ONUNLOAD/ONLOAD DATABASE |
| IC87066 | CDR THREADS NAMES ARE NOT CLEANED UP FROM SYSMASTER:SYSTHREADS TABLES EVEN THOUGH THREADS ARE NO LONGER PRESENT ON THE SERVER. |
| IC87067 | SETTING UP A REPLICATE BETWEEN IDS 10.00 AND 11.70 CAN FAIL WITH DIFFERENT SYMPTOMS |
| IC87070 | USAGE OF MENU DRIVEN TABLE MODIFICATION CHANGED BETWEEN 11.50 AND 11.70 |
[{"Product":{"code":"SSGU8G","label":"Informix Servers"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"--","Platform":[{"code":"PF002","label":"AIX"},{"code":"PF010","label":"HP-UX"},{"code":"PF016","label":"Linux"},{"code":"PF027","label":"Solaris"},{"code":"PF033","label":"Windows"}],"Version":"11.7;11.70","Edition":"Developer;Express;Growth;Innovator;Ultimate","Line of Business":{"code":"LOB10","label":"Data and AI"}}]