Problem

Kernel panic occurs after configuring ServeRAID controller for Servers.

Resolving The Problem

Source
RETAIN tip H174226

Symptom
If the ServeRAID controller is configured and attached to drives after installing Red Hat Linux 7.1 using the onboard Adaptec controller, kernel panics occurs.

Affected configurations

The system may be any of the following IBM eserver xSeries servers:

  • An xSeries 370, type 8681, any model
  • An xSeries 350, type 8682, any model
  • An xSeries 342, type 8669, any model
  • An xSeries 340, type 8656, any model
  • An xSeries 330, type 8674, any model
  • An xSeries 330, type 8654, any model
  • An xSeries 300, type 8672, any model
  • An xSeries 240, type 8664, any model
  • An xSeries 232, type 8668, any model
  • An xSeries 230, type 8658, any model
  • An xSeries 220, type 8646, any model
  • An xSeries 220, type 8645, any model
  • An xSeries 200, type 8481, any model
  • An xSeries 200, type 8479, any model
  • An xSeries 200, type 8478, any model

The system may be any of the following IBM Netfinity servers:

  • A Netfinity 8500R server, type 8681, any model
  • A Netfinity 7100 server, type 8666, any model
  • A Netfinity 6000R server, type 8682, any model
  • A Netfinity 5600 server, type 8664, any model
  • A Netfinity 5100 server, type 8658, any model
  • A Netfinity 5000 server, type 8659, any model
  • A Netfinity 4500R server, type 8656, any model
  • A Netfinity 4000R (US) server, type 8652, any model
  • A Netfinity 4000R (Non-US) server, type 8653, any model

The system is configured with the following options:

  • a PC ServeRAID SCSI Adapter, Option part number 70G8489, replacement part number (FRU) 06H9334
  • a Netfinity ServeRAID-3H Ultra2 SCSI Adapter, Option part number 01K7207, replacement part number (FRU) 01K7396
  • a Netfinity ServeRAID-3HB Ultra2 SCSI Adapter, Option part number 37L6086, replacement part number (FRU) 01K7396 (adapter), replacement part number (FRU) 09L2105 (cache)
    (ServeRAID-3H Battery Backup Cache, Option part number 28L1003, replacement part number (FRU) 09L2105)
  • a Netfinity ServeRAID-3L Ultra2 SCSI Adapter, Option part number 01K7364, replacement part number (FRU) 01K7352
  • a Netfinity ServeRAID-4H Ultra160 SCSI Controller, Option part number 37L6889, replacement part number (FRU) 37L6892
  • a Netfinity ServeRAID-4L Ultra160 SCSI Controller, Option part number 37L6091, replacement part number (FRU) 09N9540
  • a Netfinity ServeRAID-4M Ultra160 SCSI Controller, Option part number 37L6080, replacement part number (FRU) 37L7258
  • a Netfinity ServeRAID-4M Ultra160 SCSI Controller (Japan), Option part number 19K0565, replacement part number (FRU) 00N9543 (Japan)
  • a ServeRAID II Ultra SCSI Adapter, Option part number 76H3584, replacement part number (FRU) 76H3587
  • a ServeRAID-4Lx Ultra160 SCSI Controller, Option part number 06P5740, replacement part number (FRU) 06P5741
  • a ServeRAID-4Mx Ultra160 SCSI Controller, Option part number 06P5736, replacement part number (FRU) 06P5737

The Red Hat, version 7.1 network operating system (NOS) is affected.

Solution
If the system BIOS has the boot priority setting, verify that it is set to "Onboard SCSI".

  1. Edit /etc/modules.conf  and change the loading order of the ips and aic7xxx modules to the following:

    alias scsi_hostadapter aic7xxx
    alias scsi_hostadapter1 ips

  2. Make a new init ramdisk: mkinitrd -f /boot/initrd-2.4.2-2.img 2.4.2-2
  3. Run: lilo -v
  4. Reboot

Additional information
Kernel panic results in the ips module being loaded before the Adaptec module.

Document Location

Worldwide

Operating System

Older System x:Red Hat Linux

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW18G","label":"Older System x->xSeries 200"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW18H","label":"xSeries 220"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW18J","label":"Older System x->xSeries 230"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW18K","label":"Older System x->xSeries 240"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW18L","label":"Older System x->xSeries 330"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW18M","label":"Older System x->xSeries 340"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW18Q","label":"System x->xSeries 232"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW18T","label":"Older System x->xSeries 300"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW18U","label":"Older System x->xSeries 342"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW18V","label":"Older System x->xSeries 350"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW18W","label":"Older System x->xSeries 370"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWN05","label":"Older System x->Netfinity 5000"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWN07","label":"Older System x->Netfinity 8500R"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWN08","label":"Older System x->Netfinity 5600"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWN09","label":"Older System x->Netfinity 4000R"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWN10","label":"Older System x->Netfinity 5100"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWN11","label":"Older System x->Netfinity 7100"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWN12","label":"Older System x->Netfinity 6000R"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWN13","label":"Older System x->Netfinity 4500R"},"Platform":[{"code":"PF042","label":"Caldera"}],"Line of Business":{"code":"","label":""}}]