Problem

Java Runtime Version Mismatch error appears in the IBM Rational(R) Robot Console window when testing an HTML or Java application with a GUI script. For example, Java Runtime Version Mismatch: Expected (8.0.0.5) Actual (8.0.0.7) appears

Cause

The Java Runtime Environment (JRE) used to run the application is enabled with a Java Enabler that is out of sync with Robot

Resolving The Problem

Rerun the Java Enabler.

  • Select Start > Programs > Rational Software > Rational Test > Java Enabler
  • Make sure that Robot is closed before running the enabler
  • The Java enabler must be rerun whenever a new JRE is installed that will be used to run an application being tested by Robot



[{"Product":{"code":"SSSHDX","label":"Rational Robot"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"Recording","Platform":[{"code":"PF033","label":"Windows"}],"Version":"2001a;2001a.04.00;2002;2002.05.00;2002 Release 2;2002.05.20;2003;2003.06.00","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}},{"Product":{"code":"SSSHDX","label":"Rational Robot"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":null,"Platform":[{"code":"","label":""}],"Version":"","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]