How To
Summary
Novell NetWare v4.2 installation for the IBM Netfinity 1000 server.
Steps
Revision Level: 1.0Updated: 03/09/2000
Supported systems
8477 ZRY
Follow the network operating system (NOS) installation instructions provided in this document sequentially unless you are instructed differently. Windows and messages might differ from those in this document.
Sections within this document
1.0 What you will need
2.0 Where to download device drivers/files
3.0 Quick installation instructions for experienced users
4.0 Setting up the hardware for NetWare 4.2 installation
4.1 Setting up the basic input/output system (BIOS)
4.2 Installing NetWare 4.2
1.0 What you will need
- A phillips-head screwdriver (for removing thumbscrews)
- Supported hard disk drives (Click here to view a list of supported options and part numbers for your server .)
- A licensed copy of Novell NetWare 4.2
- A Netfinity 1000/3000 Flash BIOS Update Diskette version 1.29
- A Netfinity 7100/7600 - 7800 Family Manager Set for OS/2 and NetWare
- A licensed copy of MS-DOS 6.22 or later or a PC-DOS 6.3 or later
- IBM 10/100 Fault Tolerant Ethernet Adapter Files
2.0 Where To download device drivers/files
Novell FTP site: ftp://ftp.novell.com/pub/updates/nw/nw51
Novell Web site: http://support.novell.com/misc/patlst.htm
Novell Web site: http://developer.novell.com/devres/sas/driver/ddrivers.htm (for IDECD.CDM driver)
If you are very familiar with the installation process, continue to reference 3.0 Quick installation instructions for experienced users. If you are not, continue to reference 4.0 Detailed installation instructions.
3.0 Quick installation instructions for experienced users
Insert the CD labeled NetWare 5 Operating System and start (boot) the system to run the installation program.
4.0 Setting up the hardware for NOS installation
Remove the top panel by loosening the thumbscrews at the back upper corners of the server. Remove the top access panel by pushing it toward the rear of the system.
For the initial installation, install all of the microprocessors that you plan to use, and remove all adapters and devices that are not required to get the base operating system installed. (For example, if you are installing multiple network adapters, only install one now. If you are using a tape drive or external SCSI devices, disconnect them temporarily.) After the operating system starts without errors, add these devices one at a time. This procedure simplifies the installation process.
NOTE : When you install additional microprocessors, be sure that a microprocessor or a terminator card is in slot 4. If you plan to use an external DASD enclosure, the following instructions do not apply. Refer to the documentation provided with the external enclosure for the correct setup. Continue to reference 4.2 Setting up the BIOS.
3. Close the top panel.
4. Install the desired number of hot-swap hard disk drives into the hot-swap bays beginning at the top bay and proceeding downward.
4.1 Setting up the BIOS
Power on the server and when the IBM logo appears, press F1 to enter Configuration/Setup .
When the Configuration/Setup Utility menu appears, move the highlighted selection to Load Default Settings and press Enter . Press Enter again to return to the Configuration/Setup Utility menu.
Click here to verify that you are at the latest level of BIOS .
Determine the version of BIOS running on your server by highlighting the menu option System Information, select Product Data , and press Enter . The Flash EEPROM Revision Level field contains the BIOS version. The numbers in position 5, 6, and 7 of the level represent the current BIOS level. For example, OSJT23AUS is BIOS level 23A, U.S. English.
Press Esc twice to return to the Configuration Utility menu. If you determine that your BIOS does not need to be updated, skip to step 8.
If your BIOS needs to be updated, download the appropriate image and build the diskette image by running the .exe file. Answer Y on the last page of the licensing agreement. The current diskette image is V1.29A.IMG and is labeled Netfinity 1000/3000 Flash BIOS Update Diskette version 1.29. Exit Setup and save the settings.
Start (boot) with the BIOS diskette in the server and answer the question appropriately. After the BIOS update is complete, you might receive a "162 Configuration has changed" error on startup (boot); ignore this message. Setup will start and you can continue with step 8.
NOTE: If you do not see the "162 Configuration has changed" message at startup (boot) time, press F1 when the IBM logo appears to enter Setup .
8. Move the highlighted selection to Start Options and press Enter .
9. Verify that the Startup Options are set to the following (change if necessary):
First Startup Device - Diskette 0
Second Startup Device - CD-ROM
Third Startup Device - Hard Disk 0
Fourth Startup Device - Disabled
10.Press Esc to return to the main menu.
11.Select Save Settings on the Configuration/Setup Utility window, press Enter twice, select Exit Setup , and select Yes to exit the Setup Utility .
12.The server will restart. If you receive a "162 Configuration Change has Occurred" message during post, press Enter to select Continue and press Enter again. At the Diagnostic/Setup Utility window, press Esc and press Enter to select Yes, save and exit the Setup Utility .
4.2 Installing NetWare 4.2 using the integrated SCSI controller
DOS installation
Install DOS. Be sure to create a DOS partition between 50 MB and 2 GB in size. Novell recommends 50 MB for typical installations.
After installing DOS, restart the server. If you receive a message "Virus Warning", ignore it and select Change is expected .
Loading the IDE CD-ROM Device Driver
Insert the IDE CD-ROM Support Package diskette and type A:\Uinstall .
Follow the on-screen instructions.
Using a standard text editor, determine if the following lines are contained within the CONFIG.SYS on C:. If they are, type REM at the beginning of each line:
DOS=HIGH
DEVICE=C:\DOS\HIMEM.SYS
DEVICE=C:\DOS\EMM386.EXE
NOTE : Since D is the default drive letter for the CD-ROM drive, D: is used in all of the following examples to indicate the CD-ROM drive. In case you have chosen to change the default drive letter assignment, substitute the drive letter you have chosen for the D: in these examples.
NetWare 4.2 software installation
Restart the server and insert the NetWare 4.2 Operating System CD into the CD-ROM drive. Move to the CD-ROM drive letter D: and type Install .
Select the language you want to install.
Read through the licensing terms and press Enter as necessary.
From the Choose the product you want to install window, select NetWare 4.2 .
From the Select the type of installation you are performing window, select Custom installation of NetWare 4.2 .
NOTE : If you receive a message stating that "The DOS partition size is not correct", select Yes to proceed in spite of this condition.
6. Enter the Server Name and press Enter .
7. Unless you have a specific method of setting internal IPX numbers, accept the default by pressing Enter .
8. Press Enter to accept the default source and the destination directories for the installation process. The server boot files will now be copied to the DOS partition.
9. Select Select a locale configuration for the server .
10.Select Yes at the Do you want to modify, add, or delete any special startup set commands? prompt. Add the following commands:
Set maximum packet receive buffers=500
Set minimum packet receive buffers=100
Set maximum concurrent disk cache writes=2000
11.Press F10 to save and continue.
12.Specify whether or not you wish to add commands to AUTOEXEC.BAT to load SERVER.EXE (automatically load NetWare upon server startup) and press Enter . The default is No. If you choose to add the commands, specify the path to AUTOEXEC.BAT and press Enter .
13.NetWare now scans for available disk controller drivers. Press Enter when the following message is displayed:
"Install found the following hardware but found more then one driver supporting this hardware. PCI.8086.xxxx.xxxx.xxxx.xx."
14.Select Select additional driver or modify selected Disk/Lan drivers .
15.Press Enter to select Network (Lan) drivers.
16.Press Insert to install an unlisted device driver.
17.Insert the Netfinity and PC Server Ethernet Controller Device Driver diskette into the diskette drive, and press F3 .
18.Enter the correct path for the driver and the operating system (OS). Press Enter and select IBMFE.LAN .
19. Reply No to all the save existing file questions, ignore any warnings, and continue to overwrite existing files.
20.Select Select/Modify driver parameters to set the Slot Number for the on-board Ethernet adapter. The default Slot number is usually 10006 for this server.
21.Scroll to and select Save parameters and continue .
22.Select Yes to specify any additional drivers, or select No to continue with the installation.
23.Select Continue installation .
24.Select Continue installation .
25.You might receive a message about adapters with multiple ports or channels stating that their particular driver did not load. If you are not using all of the ports or channels, this failure message is normal and it should be ignored. Press Enter to continue the installation.
26.For Create NetWare Partitions, select Automatically .
27.Review the NetWare message that lists the amount of free disk space for the system and press Enter .
28.At the next window, press Insert and press Enter on a volume name to change its size. Press F10 to save the change, or press F10, press Enter to accept these default volume configurations, and continue the installation.
29.Press Enter at the Protocol Options menu to continue the installation using only IPX, or if you want to add protocols other than IPX, at the Protocol Selection window highlight View/Modify Protocol Settings , and press Enter twice.
NOTE : To install additional protocols, you need to supply additional information at the Protocol Settings window and then press Esc to return to the Protocol Selection window. Select Continue with installation when the protocol configuration is complete. If you receive a message stating that the CDROM.NLM did not load in time, this message is normal because the NW42 volume on the CD-ROM is very large. the installation process will continue as soon as the CD volume mounts.
30.Press Enter to accept a preliminary installation path, or press F3 for a different path. If you want to change the path, type the new path name and press Enter twice. The system performs a Preliminary Copy.
31.After the preliminary copy is complete, select Yes this is the first NetWare 4 server , or select No to connect existing NetWare 4 network .
If you select Yes :
Enter the Directory name and press Enter .
Select the appropriate time zone.
Review the settings for the time and Date and press Enter on any item to modify its value, or press F10 to accept the values and continue the installation process.
Specify the Company or Organization (normally the Directory Tree name again), any additional suborganizations, and press Enter .
Enter your Administrator password twice and press Enter after each entry.
Select Yes to save the Directory Information.
If you select No :
The network is checked for existing NetWare Servers.
NOTE: A Master or Read/Write Replica Server in the NDS tree must be active before any given tree appears in the list.
2. Select an NDS tree to which to connect.
3. Select the appropriate time zone.
4. Review the settings for the time and date, press Enter on any item to modify its value, or press F10 to accept the values, and continue the installation process.
5. Enter the administrator password for that server and press Enter .
6. Specify any additional suborganizations and press Enter .
7. Select Yes to save the Directory Information.
31.Setup prints out a report of the Directory information to copy. When you have completed copying this information, press Enter to continue.
NOTE: The use of a duplicate license diskette causes unpredictable results and is a violation of the Novell NetWare License Agreement.
32.Insert the License Diskette for your version of NetWare, press Enter , or press F3 to specify a location other than the A: drive.
33.A message stating that "The Server Connection License Was Successfully Installed" will appear. Press Enter and remove the License Diskette.
34.Make any desired changes to the STARTUP.NCF, press F10 , and select Yes to confirm the changes.
35.Make any desired changes to the AUTOEXEC.NCF, press F10 , and select Yes to confirm the changes. NetWare now performs the main file copy to the hard disk drive.
36.When the copy is complete, select Continue Installation to exit.
37.The system displays the message "The server installation of NetWare 4.2 is complete." Press Enter . If you do not have multiple CPUs installed in your system, the installation of NetWare 4.2 is now complete.
38.If you do have multiple CPUs installed, at the server console type Load install.
39.At the Installation Options menu, select Multi CPU options.
40.From the SMP Installation Options menu, select Select a Platform Support Module .
41.From the Select a driver menu, select MPS14.PSM .
42.Select Yes .
43.Press Enter to continue.
44.Press Esc twice to Exit the installation program and select Yes.
NOTE: ODI 3.31 drivers are installed by default. If you have a driver that will not load, obtain a new version of the driver that is ODI 3.31 compliant.