How To
Summary
To obtain a formatted listing of the VTOC and the VTOCIX, IEHLIST utility LISTVTOC parameter can be used. Review the steps section of this document for more information.
Steps
//STEP1 EXEC PGM=IEHLIST
//SYSPRINT DD SYSOUT=A
//DD1 DD UNIT=3390,VOLUME=SER=volser,DISP=OLD
//SYSIN DD *
LISTVTOC FORMAT,VOL=3390=volser,INDEXDSN=SYS1.VTOCIX.volser
/*
View the output from the IEHLIST job. The following sections display the sizes and locations of the VTOC and VTOCIX.
The FORMAT 4 section describes information pertaining to the VTOC. The size of the VTOC is the difference between the high and the low cylinders labeled LOW(C-H) HIGH(C-H)
FORMAT 4 DSCB NO AVAIL/MAX DSCB /MAX DIRECT NO AVAIL NEXT ALT FORMAT 6 LAST FMT 1 VTOC EXTENT THIS DSCB
VI DSCBS PER TRK BLK PER TRK ALT TRK TRK(C-H) (C-H-R) DSCB(C-H-R)/LOW(C-H) HIGH(C-H) (C-H-R)
81 20540 50 45 0 0 0 61 14 50 2 0 61 14 2 0 1
NUMBER OF MULTICYLINDER UNITS
CYLINDERS FIRST CYL ADDR SPACE
70119 65520 21
The VTOCIX section describes information pertaining to the VTOCIX. The size of the VTOCIX is the difference between the high and the low cylinders labeled LOW(C-H) HIGH(C-H)
SYS1.VTOCIX.ZSSMS9 ZSSMS9 1 2019.295 00.000 00.000 1 PS F 00 8192
SMS.IND LRECL KEYLEN INITIAL ALLOC 2ND ALLOC EXTEND LAST BLK(T-R-L) DIR.REM F2 OR F3(C-H-R) DSCB(C-H-R)
SU 8192 TRKS CONTIG 0 899 6 0 2 0 3
EATTR
NS
EXTENTS NO LOW(C-H) HIGH(C-H)
0 121 0 180 14
Document Location
Worldwide
Was this topic helpful?
Document Information
Modified date:
24 March 2022
UID
ibm16566173