Troubleshooting
Problem
RETAIN tip: H212641
Symptom
While attempting to upgrade the controller firmware on an IBM System Storage DS Storage Controller, the following message might be received:
This tip is not software specific.
No fix is forthcoming for this issue. See the Workaround section for instructions on how to proceed if this error is encountered.
Workaround
| [pre-upgrade tests] [check spm database]
An error occurred while checking the spm database on controller A. |
If this message is received, the controller firmware upgrade has failed.
Affected configurations
The system can be any of the following IBM servers:
- DS4200 Storage Server, type 1814, any model
- DS4300 (FAStT600) Dual Controller and Turbo Storage Server, type 1722, any model
- DS4300 (FAStT600) Single Controller Storage Server, type 1722, any model
- DS4500 (FAStT900) Storage Server, type 1742, any model
- DS4700 Storage Server, type 1814, any model
- DS4800 Storage Server, type 1815, any model
- IBM System Storage DS3200, type 1726, any model
- IBM System Storage DS3300, type 1726, any model
- IBM System Storage DS3400, type 1726, any model
- IBM System Storage DS3950 Express, type 1814, any model
- IBM System Storage DS5020 Disk Controller (1814-20A), any model
- IBM System Storage DS5100 Storage Controller, type 1818, any model
- IBM System Storage DS5300 Storage Controller, type 1818, any model
This tip is not software specific.
This tip is not option specific.
Solution
No fix is forthcoming for this issue. See the Workaround section for instructions on how to proceed if this error is encountered.
Workaround
Use a level of Storage Manager Client earlier than level 10.86 in order to perform the controller firmware upgrade. After the upgrade has completed, upgrade the Storage Manager Client to the 10.86 level if desired.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"HW2F2","label":"Disk systems->DS5300"},"Component":"--","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"Version Independent","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"HW2H2","label":"Disk systems->DS5020"},"Component":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"Version Independent","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"HW2E2","label":"Disk systems->DS5100"},"Component":" ","Platform":[{"code":"","label":""}],"Version":"","Edition":"","Line of Business":{"code":"","label":""}}]