IBM Support

Flat File adapter fails to process BOs in file after poll quantity

Troubleshooting


Problem

During inbound operation for Flat File, using splitting and pollquantity=n, BO number=n+m, m can not be transacted correctly. This has been identified as a product defect under APAR JR37548.

Symptom

While processing files, if using both file splitting and a poll quantity smaller than the file splitting size, the adapter will drop events after processing the poll quantity number up to the file split size. The dropped events will not be processed, though they do show up in the poll tracing.

Resolving The Problem

The Fix Pack with the code fix for this issue has been released as part of WebSphere Adapter for Flat Files 7.0.0.3. Documentation is in this fix level.


This fix is packaged as a part of WebSphere Integration Developer 7.0.0.3, with details and installation instructions.


By installing this tooling fix level and upgrading the version of the adapter used by the adapter, this issue can be corrected. Alternatively, by setting the poll quantity to a value larger than the file splitting size the issue can also be worked around without applying a code fix.

[{"Product":{"code":"SSMKUK","label":"WebSphere Adapters Family"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"Adapter for FlatFiles","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0;7.0.0.1;7.0.0.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
15 June 2018

UID

swg21447414