IBM Support

"Failed to initialize" message when updating Integrated Management Module (IMM) via Command Line Interface (CLI) - IBM System x

Troubleshooting


Problem

When updating Integrated Management Module (IMM) firmware via the Command Line Interface (CLI), the system may display the following error message: Firmware Update: Failed to initialize. Please try again. This error is expected to occur very infrequently.

Resolving The Problem

Source

RETAIN tip: H197835

Symptom

When updating Integrated Management Module (IMM) firmware via the Command Line Interface (CLI), the system may display the following error message:

  Firmware Update: Failed to initialize. Please try again.

This error is expected to occur very infrequently.

Affected configurations

The system may be any of the following IBM servers:

  • System x3690 X5, type 7148, any model
  • System x3690 X5, type 7149, any model
  • System x3850 X5, type 7145, any model
  • System x3850 X5, type 7146, any model
  • System x3950 X5, type 7145, any model

This tip is not software specific.

This tip is not option specific.

The following system firmware level(s) are affected:

  • IMM yuoo75t

Solution

This behavior is fixed in IMM firmware 91E or newer.

The file is available by selecting the appropriate Product name, Product machine type, and Operating system on IBM Support's Fix Central web page, at the following URL:

Workaround

One of the following two (2) workarounds should be performed:

Workaround 1:

  Reboot the IMM.

Workaround 2:

  Update using the standard package from within the Operating System (OS).

Additional information

The root cause of the issue is the IMM thinks that another flash update is in progress. Flash update methods performed within the OS avoid the issue because they use a different process method for flashing.

Document Location

Worldwide


Operating System

System x:All operating systems listed


Applicable countries and regions

  • Worldwide
[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWXB0","label":"System x->System x3690 X5"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWXC0","label":"System x->System x3850 X5"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWXD0","label":"System x->System x3950 X5"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]

Document Information

More support for:
System x->System x3690 X5

Document number:
857962

Modified date:
30 January 2019

UID

ibm1MIGR-5086168

Manage My Notification Subscriptions