Troubleshooting
Problem
The customer is attempting to download a file via SFTP Get in Sterling B2B Integrator. When the file is small(in the KBs) they are able to download it successfully. When the file is larger (in the Mbs) then they get the following error and the file fails to download: Negative message length in SFTP protocol:[Unknown cause]
Symptom
The error in sftp.log is:
[2015-12-31 10:12:33.829] DEBUG Session.get(GR,GR,PT) get data from remote file=[/OUTBOUND/Other/8000021391893_0000000000215_20151124_075508_BulkAcct.ack.pgp].
[2015-12-31 10:12:34.303] ERROR Session.failedSequence(S,R) Negative message length in SFTP protocol. [Unknown cause]
[2015-12-31 10:12:34.303] DEBUG Response.sendResults - Entered. Time - 1451578354303
There is no stack trace associated with the error.
PSLogger doesn't show any error.
wf.log says:
[2015-12-31 10:12:34.306] WARN 000000000000 WORKFLOW.ACTIVITY.ERR_ServiceMetaData_getParmVersion [ServiceMetaData.getParmVersion] Can not get sii from SftpClientAdapter
[2015-12-31 10:12:34.306] DEBUG msg Hash={}
[2015-12-31 10:12:34.306] DEBUG 000120010298 WORKFLOW.WORKFLOW.DEB_iwfc_content iwfc.content {Status=1, ErrorMessage=Negative message length in SFTP protocol. [Unknown cause], ServiceStartTime=2015-12-31 10:12:33.676, ServiceEndTime=2015-12-31 10:12:34.303}
[2015-12-31 10:12:34.306] DEBUG 000120010883 WORKFLOW.WORKFLOW.DEB_setWFContent setWFContent(): set Status to(->) 1 , append = false )
[2015-12-31 10:12:34.306] DEBUG 000120010981 WORKFLOW.WORKFLOW.DEB_setWFContent1 setWFContent(): AI =
null
Log InLog in to view more of this document
Was this topic helpful?
Document Information
Modified date:
14 November 2019
UID