Problem

Error messages and their corrective measures for PC Server 300

Resolving The Problem

<</font>

Error Message/Symptom FRU/Action
Arithmetic Functions Failed
An error was detected during the CPU Test.
1. Microprocessor
2. System Board
Base Memory Test Failed
An error was detected in base memory.
1. Memory Module
2. System Board
Battery Error 1. Replace the battery and run Setup.
2. System Board
Boot Sector Unreadable
A boot sector read error was detected on the hard disk drive.
1. Hard Disk Drive
2. Hard Disk Drive Cable
3. Hard Disk Drive Adapter (if installed)
4. System Board
Bus Noise Test Failed
The RAM Test detected an error in the memory bus.
1. Memory Module
2. System Board
Butterfly Cylinder Access Test Failed
The Hard Disk Drive Test detected mismatch between the data read and the data stored on the drive.
1. Hard Disk Drive
2. Hard Disk Drive Cable
3. Hard Disk Drive Adapter (if installed)
4. System Board
Clock Stopped
The real-time clock has stopped working.
1. Real-Time Clock Assembly
2. System Board
CMOS Clock Test Failed
The Time and Date Settings for CMOS and DOS do not Match.
1. Real-Time Clock Assembly
2. System Board
COM Port Tests Failed
Test failed with wrap plug attached.
1. Serial Cable
2. System Board
Controller Diagnostic Test Failed
An error was detected while testing the Hard Disk
Controller (Adapter).
1. Hard Disk Drive Adapter (if installed)
2. Hard Disk Drive
3. System Board
Cylinder 0 errors
The test detected an error reading the first cylinder of the hard disk drive.
1. Hard Disk Drive
2. Hard Disk Drive Adapter (if installed)
3. System Board
Device is Not Ready
Ready the Device...
or
Press Any Key
1. Ensure the device is powered-on
2. Replace failing device
3. Device Adapter (if installed)
4. System Board

Disk Error Encountered Opening Output File Press Any Key To Continue. 1. Hard Disk Drive
2. Hard Disk Drive Adapter (if installed)
3. System Board
DMA #X Failed
The Main Components Test detected an error while testing the DMA controller.
1. System Board
DMA Page Register Failed
An error was detected while outputting all possible values to the DMA Page Register.
1. System Board
Door Is Open
1. Close door on device being tested.
2. Device being tested
3. System Board
Drive (x) Media (y) Mismatch
The capacity listed for the drive in the File Allocation Table ID does not match the calculated capacity of the drive.
1. Check diskette and diskette drive capacity.
2. Diskette Drive
3. System Board
EISA Configuration NVRAM Bad 1. Replace battery, then run Setup.
2. System Board
Error in video buffer. Bad bits
The video memory test failed.
1. Video Adapter
2. System Board
3. Display
Exception Interrupt In Protected Mode Diags Cannot Continue
Server error, all system tests will stop. Remove one adapter at a time until the symptom goes away.
1. Any Adapter
2. System Board
3. Processor
Extended Memory Test Failed
An error was detected in Extended Memory.
1. Memory Module
2. System Board
FF Stuck Key
Keyboard error
1. Keyboard
2. System Board
Floppy Drive Failed
One or more diskette drives failed.
1. Diskette Drive
2. System Board
3. Diskette Drive Cable
General Function Failed
Remove one adapter at a time until the symptom goes away.
1. Any Adapter
2. System Board
3. Processor
Hard Drives Failed
One or more of the Hard Disk Drive tests detected an error.
1. Hard Disk Drive
2. Hard Disk Drive Adapter (if installed)
3. System Board

Incorrect DOS version 1. Ensure you are using DOS version 3.0 or higher.
Insert A Data Disk 1. Insert a known good data disk into the CD-ROM.
2. CD-ROM Drive
3. System Board
4. CD-ROM Cable
INT Mask Register Failed
The INT Mask Register tests detected an error.
1. Microprocessor
2. System Board
Invalid Date
The back-up clock and DOS dates do not match.
1. Real-Time Clock Assembly
2. System Board
Invalid Time
The back-up clock and DOS time of day settings do not match.
1. Real-Time Clock Assembly
2. System Board
Keyboard Error
One or more keys do not operate correctly.
1. Keyboard
2. System Board
Linear Cylinder Access Test Failed
Hard disk drive error. The redundancy check of the sectors read does not match the information on the drive.
1. Hard Disk Drive
2. Hard Disk Drive Cable
3. Hard Disk Drive Adapter (if installed)
4. System Board
Logic Function Failed
The CPU Logic Test has detected an error.
1. Microprocessor
2. System Board
Loopback Error
An error occurred during the COM Port Test or Parallel Port Test.
NOTE: A wrap plug must be installed to successfully complete these tests.
1. System Board
2. Wrap Plug
Main Components Failed
A component failure was detected on the system board.
1. System Board
2. Processor
Memory test cannot run at this location in memory
Not enough free memory available to start the memory test.
1. Memory Module
2. System Board

Missing QAPlus/PRO Files(s)
One or more Diagnostic support files are missing.
1. Diagnostic Diskette
NO LOOP-BACK PLUG.
Skipping External loopback test
No wrap plug installed.
1. Install wrap plug on the serial port, rerun test.
2. System Board
Not ready
Printer not on-line or not ready.
1. Ready Printer
2. Printer
3. Printer Cable
4. System Board
Not ready error, ready drive A
DMA Transfer test error
1. Ensure that a known good formatted diskette is in drive a, then rerun the test.
2. System Board
No 'type-amatic' repeat
NOTE: At least one repeat key must be tested during this test or an error will occur.
The Type-amatic test detected an error.
1. Keyboard
2. System Board
Not used by any standard device
The IRQ is not currently being used by a non-standard device.
1. System Board
Numeric Proc Failed
The NPU TEST detected an error.
1. Microprocessor
2. System Board
Parallel Ports Failed
Test Report Summary message.
1. System Board
Pass (N): ** Errors ** Drive (X) Failed
The read/write test failed on the diskette drive.
1. Diskette Drive
2. System Board
3. Diskette Drive Cable
Pass (N) Drive Not Ready
The diskette drive door is open or defective.
1. Ensure diskette drive is ready.
2. Diskette Drive
3. System Board
4. Diskette Drive Cable
Pass (N): Drive (X) Write Protected or Unformatted 1. Insert a non-write protected, formatted diskette into the diskette drive; the rerun the test
2. Diskette Drive
3. System Board
4. Diskette Drive Cable
Pass (N): Unknown Media Drive (X)
Diskette Drive Test error.
The File Allocation Table ID on the diskette is invalid.
1. Diskette
2. Diskette Drive
3. System Board
4. Diskette Drive Cable
Place Hi-density Media in Drive
The capacity of the diskette installed in the diskette drive is less then the capacity of the drive.
1. Diskette
2. Diskette Drive
3. System Board
4. Diskette Drive Cable
Printer Failed
Ensure the printer is powered-on and ready.
1. Printer
2. Printer Cable
3. System Board
Printer Fault
Ensure the printer is powered-on and ready.
1. Printer
2. Printer Cable
3. System Board
Printer Not Selected
Ensure the printer is powered-on and ready.
1. Printer
2. Printer Cable
3. System Board
Program or File Not Found
Press Any Key
The diagnostics cannot find the USER(N).COM file.
1. Diagnostic Diskette
2. Diskette Drive
3. System Board
Program Too Big To Fit In Memory
Too many Terminate and Stay Resident programs in memory while loading diagnostics.
1. Reboot the system from the Diagnostic Diskette
QAPlus/PRO Cannot Be Re-run Because Of Error In Relocating Program
Diagnostics failed to relocate the Diagnostics Test programs so the memory space it resides in was not tested.
1. Diagnostic Diskette
2. Memory Module
3. System Board
RAM Memory Error in Block n. Bad bits n
An error was detected in RAM.
1. Memory Module
2. System Board
RAM Test Failed
Test Result Summary message, Memory Test failed.
1. Memory Module
2. System Board
Read error on cylinder n
Hard disk drive physical format error.
1. Hard Disk Drive
2. Hard Disk Drive Adapter (if installed)
3. System Board

Read Errors
Diskette drive read error.
 
1. Diskette
2. Diskette Drive
3. System Board
4. Diskette Drive Cable
Receive Error
Serial Port loopback test error.
1. Serial Port Cable
2. System Board
Refresh Failure
The Diagnostics Test detected an error while testing the DMA controller's RAM refresh cycle.
1. Memory Module
2. System Board
RTC Interrupt Failure
The Diagnostics Test cannot detect the Real-Time clock interrupt.
1. Real-Time Clock Assembly
2. System Board
Serial Chip Error
COM Port error, general.
1. Serial Port Cable
2. System Board
Serial Compare Error
COM Port error, information transmitted is not the same as information received.
1. Serial Port Cable
2. System Board
Serial Time-out Error
COM Port error, time interval is too long between transmitted and received data.
1. Serial Port Cable
2. System Board
Serious Memory Error - Diags Cannot Continue
Memory Test error.
1. Memory Module
2. System Board
Sorry You Need A Mouse
The mouse or mouse driver was not detected.
1. Mouse
2. System Board
System Hangs
(while loading a diagnostic test)
1. System Board
System Hangs
Go to " Undetermined Problems ".
 
1. Any device
2. Any adapter
3. System Board
Too Many Errors - Test Aborted
Too many errors, the Diagnostics Test cannot continue.
1. Microprocessor
2. System Board
Transmit Error
Internal or external serial port loopback test failure.
1. Serial Port Cable
2. System Board
Unable To Detect CD-ROM
 
1. CD-ROM Drive
2. System Board
3. CD-ROM Cable
Video Adapter Failed
Test Result Summary, displayed if "Fail" was at the Quit/Fail/Pass menu of any video test.
1. Video Adapter
2. System Board
3. Display
Write error on cylinder n
Hard disk drive write error.
1. Hard Disk Drive
2. Hard Disk Drive Adapter (if installed)
Write Errors
Diskette drive write error.
1. Diskette
2. Diskette Drive
3. System Board
4. Diskette Drive Cable
Write Protected or Unformatted
The diskette is Write Protected or not formatted.
1. Insert a non-write protected, formatted diskette into the diskette drive; then rerun the test
2. Diskette Drive
3. System Board
4. Diskette Drive Cable