Problem

This technote explains how to resolve an issue that can occur where the error [] Error: Internal VIEW DB error, operation 'D_CRTYPE' on object 'INODE_OID_SET' failed: -901[], is reported in the view logs and some views become inaccessible on the view server when using IBM® Rational® ClearCase® (CC).

Symptom


The following errors are reported in the view log:


2008-10-01T15:05:19+02:00 view_server(6248): Error: view_server.exe(6248): Error: Readdir from dbid 0x800000aa failed: unknown error in view_server
2008-10-01T15:05:19+02:00 view_server(6248): Error: view_server.exe(6248): Error: Dir_lookup of dbid 0x800000aa failed: unknown error in view_server
2008-10-01T15:05:19+02:00 view_server(6248): Error: view_server.exe(6248): Error: Internal VIEW DB error, operation 'D_CRTYPE' on object 'INODE_OID_SET' failed: -901 (errno=Invalid argument)
2008-10-01T15:05:19+02:00 view_server(6248): Warning: *** db_VISTA database error -901 - system error

If the view_server for a specific view is stopped and restarted, the problem goes away. However, the problem may occur for other views on the system.

[{"Product":{"code":"SSSH27","label":"Rational ClearCase"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Component":"View: Dynamic","Platform":[{"code":"PF033","label":"Windows"}],"Version":"7.0.1.2;7.0.1.1;7.0.1;7.0.0.2;7.0.0.1;7.0","Edition":"","Line of Business":{"code":"LOB77","label":"Automation Platform"}}]