Troubleshooting
Problem
Diagnostic error codes for Netfinity 5100.
Resolving The Problem
This document is intended for trained servicers who are familiar with IBM Personal Computer products. Use this document along with advanced diagnostic tests to troubleshoot problems effectively. Before servicing an IBM product, be sure to review the safety information. Click here to review safety information.
In the following error codes, if XXX is 000, 195, or 197 do not replace a FRU. The description for these error codes are:
- 000 The test passed.
- 195 The Esc key was pressed to abort the test.
- 197 This is a warning error and may not indicate a hardware failure.
For all error codes, replace/follow the FRU/Action indicated.
| Error code/symptom | FRU/action |
|---|---|
| 001-XXX-000 (Failed core tests) |
|
| 001-XXX-001 (Failed core tests) |
|
| 001-250-000 (Failed System board ECC) |
|
| 001-250-001 (Failed processor board ECC) |
|
| 005-XXX-000 (Failed Video test) |
|
| 011-XXX-000 (Failed COM1 Serial Port test) |
System board |
| 011-XXX-001 (Failed COM2 Serial Port test) |
System board |
| 014-XXX-000 (Failed Parallel Port test) |
System board |
| 015-XXX-001 (Failed USB test) |
System board |
| 020-XXX-000 (Failed PCI Interface test) |
|
| 020-XXX-001 (Failed Hot-Swap Slot 1 PCI Latch test) |
|
| 020-XXX-002 (Failed Hot-Swap Slot 2 PCI Latch test) |
|
| 020-XXX-003 (Failed Hot-Swap Slot 3 PCI Latch test) |
|
| 020-XXX-004 (Failed Hot-Swap Slot 4 PCI Latch test) |
|
| 030-XXX-000 (Failed Internal SCSI interface test) |
System board
|
| 030-XXX-00N (Failed SCSI test on PCI slot N. Check system error log before replacing a FRU.) |
Adapter |
| 035-XXX-099 |
|
| 035-XXX-S99 (Failed RAID test on PCI slot S. Check System Error Log before replacing a FRU) |
|
|
035-XXX-SNN (Check System Error Log before replacing a FRU. |
Fixed disk with SCSI ID NN on RAID adapter in PCI slot S. |
| 035-253-S99 (RAID adapter initialization failure) |
|
| 075-XXX-000 (Failed Power Supply test) |
Power Supply |
| 089-XXX-001 (Failed Microprocessor test) |
|
| 089-XXX-002 (Failed Optional Microprocessor test) |
|
| 165-XXX-000 (Failed Service Processor test) |
|
| 180-XXX-000 (Diagnostics LED failure) |
|
| 180-XXX-001 (Failed information LED panel test) |
|
| 180-XXX-002 (Failed Diagnostics LED Panel test) |
|
| 180-XXX-003 (Failed System board LED test) |
System board |
| 180-XXX-004 (Failed processor board LED test) |
|
| 180-XXX-005 (Failed SCSI backplane LED test) |
|
| 180-XXX-006 (Memory board LED test) |
|
| 201-XXX-0NN (Failed Memory test, see "Memory Settings" in the HMM) |
|
| 201-XXX-999 (Multiple DIMM failure, see error text) |
|
| 202-XXX-001 (Failed System Cache test) |
|
| 202-XXX-002 (Failed System Cache test) |
|
| 206-XXX-000 (Failed diskette drive test) |
|
| 215-XXX-000 (Failed IDE CD-ROM test) |
|
|
217-XXX-000 (Failed BIOS Fixed disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. |
Fixed disk 1 |
|
217-XXX-001 (Failed BIOS Fixed disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. |
Fixed disk 2 |
|
217-XXX-002 (Failed BIOS Fixed disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. |
Fixed disk 3 |
|
217-XXX-003 (Failed BIOS Fixed disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. |
Fixed disk4 |
|
217-XXX-004 (Failed BIOS Fixed disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. |
Fixed disk 5 |
| 264-XXX-0NN (Failed Tape drive test) |
|
| 264-XXX-999 (Errors on multiple tape drives, see error text for more info) |
See error messages/text in the PC Doctor error log for detailed information on each individual tape drive error. |
| 301-XXX-000 (Failed Keyboard test) |
Keyboard |
| 405-XXX-000 (Failed Ethernet test on controller on the System board) |
|
| 405-XXX-00N (Failed Ethernet test on adapter in PCI slot N) |
|
| 415-XXX-000 (Failed Modem test) |
|
Document Location
Worldwide
Was this topic helpful?
Document Information
Modified date:
28 January 2019
UID
ibm1MIGR-4K8MN7