Problem
DSN9016I and DSN9023I messages occur when SAz/OS issues the DB2 shutdown command.
Symptom
DSN9016I @DBFD '-STO' COMMAND REJECTED, UNAUTHORIZED REQUEST
DSN9023I @DBFD DSN9SCND '-STO DB2' ABNORMAL COMPLETION
Cause
In this case AUTGSS had not been granted SYSOPR authority in RACF.
Diagnosing The Problem
The 2.1.2.1 Access Authority for Automation Work Operators topic in the System Automation for z/OS V3R4.0 Product Automation Programmer's Reference and Operator's Guide shows a list of SAz/OS auto operators that need SYSOPR authority.
The 1.2.7.1 Automated Function Names/OPERATORS Policy Item in the System Automation for z/OS V3R4.0 User's Guide shows that there is not always a one to one relationship between the SAz/OS Automated Function and the Automation Operator name.
Resolving The Problem
This issue was resolved by granting SYSOPR authority to AUTGSS