IBM Support

CONTAINER_0206 - MismatchedInputException: No content to map due to end-of-input

Troubleshooting


Problem

  1. The pipeline JSON file is empty or corrupted.

  2. This can occur from manual file manipulation or other problems with Data Collector’s filesystem.

Symptom

  1. When trying to load a pipeline using Control Hub’s interface, the following error occurs:

CONTAINER_0206 - Cannot load details for pipeline '<pipeline>': com.fasterxml.jackson.databind.exc.MismatchedInputException: No content to map due to end-of-input

Resolving The Problem

  1. Manually remove the pipeline directory from $SDC_HOME/data/pipelines and $SDC_HOME/data/runInfo where $SDC_HOME is Data Collector’s running directory.

  2. You can also try to remove the pipeline using the Data Collector UI.

Document Location

Worldwide


[{"Line of Business":{"code":"LOB76","label":"Data Platform"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSM7CU","label":"IBM StreamSets Data Collector"},"ARM Category":[{"code":"","label":""}],"ARM Case Number":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Version(s)"}]