IBM Support

Compound DBRW formulas are not supported in TM1 Web

Troubleshooting


Problem

TM1 Web does not support compound DBRW formulas. A compound DBRW formula is one in which a
DBRW function is used in combination with other functions and/or mathematical calculations.
Placing a minus sign before a DBRW function results in a compound formula, as this is interpreted as -1 x
(DBRW value).

If you want to display a value retrieved by a DBRW function as negative, create a cell reference with a
negative sign preceding the reference to a cell containing a DBRW function. For example, -A7, where A7
contains a DBRW function.
Some use cases may appear to work with compound formulas within TM1 Web, but they are not supported directly and thus should be avoided entirely.

[{"Line of Business":{"code":"LOB76","label":"Data Platform"},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS9RXT","label":"Cognos TM1"},"ARM Category":[{"code":"a8m0z000000blfjAAA","label":"Troubleshooting"}],"ARM Case Number":"","Platform":[{"code":"PF033","label":"Windows"}],"Version":"All Version(s)"}]