Troubleshooting
Problem
The Chassis Management Module (CMM) message "I/O module iomodule__ is incompatible with the node configuration" is expected when the CMM loses connection to the Integrated Management Module (IMM) during the time the CMM is checking the IMM for the IMM's configuration. The root cause of the problem is that the IMM restarted during the CMM check
Resolving The Problem
Check the following if you see this message:
Prior to fix pack v1.1.0.1:
- If the IMM completes restarting and you do not have PureApplication System fix pack V1.1.0.1 installed, see APAR IC96151 and the V1.1.0.1 release notes.
- IMPACT: As the IMM restarts, this message is innocuous and has no affect on the product's operation.
- RESOLUTION: Apply fix pack V1.1.0.1. which will resolve the currently known defects which cause IMM restarts.
- DETAILS: The CMM checks the IMM at regularly defined intervals. If the IMM unexpectedly restarts during one of these checks, the CMM will report the message "I/O module iomodule01 is incompatible with the node configuration." This message is expected because the CMM cannot query the IMM configuration when the IMM is in the midst of a restart. Therefore, this message is not the problem but a side-effect of the IMM restart. The root cause of that the IMM restarts. Application of fix pack V1.1.0.1 for this APAR IC96151 resolves the currently known defects which cause IMM restarts.
- If you see this message, and a message noting the IMM has not restarted, the CMM is not able to query the IMM's configuration and this would be a new problem:
- Organize what you know about the problem.
- Gather the information as indicated in our MustGather: Component level logs for V1.1 PureApplication System, chose the Chassis Management Module selection. Obtain a collection set for each Chassis Management Module.
- Contact IBM Support for PureApplication system by opening a software service request.
After fix pack v1.1.0.1 or after a newer fix pack is installed:
- If you see this message and a message noting the IMM has restarted, the CMM is not able to query the IMM's configuration and this would be a new problem:
- Organize what you know about the problem.
- Gather the information as indicated in our MustGather: Component level logs for V1.1 PureApplication System, chose the Chassis Management Module selection. Obtain a collection set for each Chassis Management Module.
- Contact IBM Support for PureApplication system by opening a software service request.
- If you see this message, and a message noting the IMM has not restarted, the CMM is not able to query the IMM's configuration and this would be a new problem:
- Organize what you know about the problem.
- Gather the information as indicated in our MustGather: Component level logs for V1.1 PureApplication System, , chose the Chassis Management Module selection. Obtain a collection set for each Chassis Management Module.
- Contact IBM Support for PureApplication system by opening a software service request.
[{"Product":{"code":"SSM8NY","label":"PureApplication System"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"Chassis Management Module (CMM)","Platform":[{"code":"PF016","label":"Linux"},{"code":"PF002","label":"AIX"}],"Version":"2.0;1.1.0.4;1.1.0.3;1.1.0.2;1.1.0.1;1.1.0.0;1.0.0.4","Edition":"","Line of Business":{"code":"","label":""}}]