Troubleshooting
Problem
This document lists Checkpoint codes followed by the routine in process and the boot mode.
Resolving The Problem
Checkpoint Codes
During POST, the computer displays the status of the components being tested in the form of Checkpoint (CP) codes in the lower left-hand corner of the screen. The following is a list of the CP codes followed by the routine in process and the boot mode.
| CP Code |
Routine | Boot Mode |
| 01 | Its_A_Reset | Cold+Warm+ Restore+Mfg+ SAD |
| 0D | Init Chip_NS | Cold+Warm+ Restore+Mfg+ SAD |
| 12 | Periph Init | Cold+Warm+ Restore+Mfg+ SAD |
| 03 | Disable Video | Cold+Warm+ Restore+Mfg+ SAD |
| 05 | Phase 1 Enter Big Real |
Cold+Warm+ Restore+Mfg+ SAD |
| B0 | Enable Local APIC | Cold+Warm+ Restore+Mfg+ SAD |
| 06 | Cache Init | Cold+Warm+ Restore+Mfg+ SAD |
| 07 | Init Refresh | Cold+Restore+ Mfg |
| 08 | Wait For RTC | Cold+Restore+ Mfg |
| 0A | Std CMOS Checksum NS |
Cold+Warm+ Restore+Mfg |
| 0B | Mid CMOS Checksum NS | Cold+Warm+ Restore+Mfg |
| 0C | Ext CMOS Checksum NS |
Cold+Warm+ Restore+Mfg |
| 0EC | SET_INIT | Cold+Warm+ Restore+Mfg+ SAD |
| 10 | Check Parity NonParity |
Cold+Warm+ Restore+Mfg |
| 11 | Disable Parity | Cold+Warm+ Restore+Mfg+ SAD |
| B1 | Init Seattle | Cold+Restore+ Mfg+SAD |
| 13 | Test CPU Regs | Cold+Restore+ Mfg |
| 14 | Init RTC | Cold+Warm+ Restore+Mfg+ SAD |
| 16 | Init Timer 0 | Cold+Warm+ Restore+Mfg+ SAD |
| 17 | Init Timer 2 | Cold+Warm+ Restore+Mfg+ SAD |
| 18 | Test DMA | Cold+Warm+ Restore+Mfg+ SAD |
| 19 | Test Page Regs | Cold+Warm+ Restore+Mfg+ SAD |
| 1A | Verify Refresh | Cold+Restore+ Mfg |
| 1B | Enable Parity | Cold+Warm+ Restore+Mfg+ SAD |
| 1C | Save ID Warm | SAD |
| 1D | Test First 64k | Cold+Restore+ Mfg |
| 1E | Clear First 64k | Cold+Warm+ Restore+Mfg |
| 1F | POST with Stack | Cold+Warm+ Restore+Mfg+ SAD |
| 20 | Enable BIOSE000 | SAD |
| 21 | BIOS Shadow | Cold+Warm+ Restore+Mfg |
| B2 | Shadow SCSI | Cold+Warm+ Restore+Mfg |
| 23 | Phase 2 POST | Cold+Warm+ Restore+Mfg+ SAD |
| 24 | Enable BIOS F000 |
SAD |
| 24 | Shadow VP D | Cold+Warm+ Restore+Mfg |
| 25 | Init Key Board Data | Cold+Warm+ Restore+Mfg+ SAD |
| 26 | Save ID | Cold+Warm+ Restore+Mfg+ SAD |
| B3 | Check P54C | Cold+Mfg |
| 27 | Init Q Boot | Cold+Warm+Restore+Mfg |
| 28 | Periph Config | Cold+Warm+Restore+Mfg+SAD |
| 2A | Init Timeout Tables |
Cold+Warm+ Restore+Mfg+ SAD |
| 2B | Pos_Setup | Cold+Warm+ Restore+Mfg |
| 2F | Test DMA Locations | Cold+Warm+ Restore+Mfg+ SAD |
| B4 | Init DMA Regs | Cold+Warm+Restore+Mfg+SAD |
| 30 | Test PICs | Cold+Warm+ Restore+Mfg+ SAD |
| 31 | Init Vector Table | Cold+Warm+Restore+Mfg+SAD |
| 32 | Enable Timer Int | Cold+Warm+ Restore+Mfg+ SAD |
| 33 | Init Keyboard | Cold+Warm+ Restore+Mfg+ SAD |
| 34 | Clear Memory Size Error | Cold+Restore+ mfg |
| 35 | Check Configuration |
Cold+Warm+ Restore+Mfg |
| 36 | Mfg Boot Fork | Cold+Restore+ Mfg |
| 37 | PCI Reset | Cold+Warm+ Restore+Mfg |
| B5 | NVRAM check | Cold+Warm+ Restore+Mfg |
| 38 | PCI Video | Cold+Warm+ Restore+Mfg |
| 3B | Sign On | Cold+Warm+ Restore+Mfg |
| 3C | Test Timer Tick | Cold+Restore+ Mfg |
| 3F | Enable Video | SAD |
| 40 | CSET BFR SIZMEM | Cold+Warm+ Restore+Mfg+ SAD |
| 41 | Size Memory Above 64k |
Cold+Warm+ Restore+Mfg |
| 42 | CSET AFT SIZ MEM | Cold+Warm+ Restore+Mfg |
| 43 | Test Timer 2 | Cold+Warm+ Restore+Mfg |
| 44 | Password Not Entered |
Cold+Restore |
| 45 | Test PS/2 Mouse | Cold+Warm+ Restore+Mfg |
| 46 | Check For Mouse Buttons | Cold+Restore |
| 47 | Init Key Board Flags |
Cold+Warm+ Restore+Mfg+ SAD |
| 48 | Test Key Board | Cold+Warm+ Restore |
| 4B | Memory Test Prompt |
Cold+Warm+Mfg |
| 4C | Test Memory | Cold+Restore+ Mfg |
| 4D | Clear EBDA | Warm |
| 4E | CSET AFT M TEST |
Cold+Warm+ Restore+Mfg |
| 4F | Allocate EBDA | Cold+Warm+ Restore+Mfg |
| B6 | Set Planar Info | Cold+Restore+ |
| 50 | xfer ebda vars | Cold+Warm+ Restore+Mfg |
| B7 | Init P54M | Cold+Warm+ Restore+Mfg |
| B8 | Init MP Structures | Cold+Warm+ Restore+Mfg |
| B9 | CPU Speed | Cold+Warm+Restore+Mfg+SAD |
| 51 | Set Warm Boot Flag |
Warm |
| 52 | Clear Speed Bits | Cold+Warm+Mfg+SAD |
| 53E | FLOB | Cold+Warm+ Restore+Mfg+ SAD |
| 54 | Enable System Interrupts | Cold+Warm+Restore+Mfg+SAD |
| 55 | C2 Security Check |
Restore |
| 56 | Init Key Board | Cold+Warm+ Restore+SAD |
| 57 | Test RTC | Cold+Warm+ Restore+SAD |
| 58 | Check For NPX | Cold+Warm+ Restore+Mfg+ SAD |
| 59 | reset hdctl | Cold+Warm+ Restore+Mfg+ SAD |
| 5A | FD INIT | Cold+Warm+ Restore+Mfg+ SAD |
| 5B | Set Floppy Config | Cold+Warm+ Restore+Mfg+ SAD |
| BA | Unlock Early | Cold+Restore |
| 5C | Init A20 | Cold+Warm+ Restore+Mfg+ SAD |
| 5D | Cache Config | Cold+Warm+ Restore+Mfg+ SAD |
| 5E | HD SETUP | Cold+Warm+ Restore+Mfg+ SAD |
| 62 | Verify CMOS Config |
Cold+Warm+ Restore+Mfg |
| 70 | Check For Setup Hot Key | Cold+Warm |
| 63 | Clear Screen | Cold+Warm+ Restore+SAD |
| BB | Init IRQ Levels | Cold+Restore |
| 65 | IBM Cirrus DDC |
Cold |
| BC | PACP Arbitration | Cold+Warm+ Restore+Mfg+ SAD |
| BD | Enable Planar SCSI |
Cold+Warm+ Restore+Mfg+ SAD |
| 66 | CSET BFR OPROM |
Cold+Warm+ Restore+Mfg |
| BE | Do ROM Scan | Cold+Warm+ Restore |
| 2C | TCPC | Cold+Warm+ Restore+Mfg |
| 49 | TCPC Errors | Cold+Warm+ Restore |
| 2D | Find Serial Ports | Cold+Warm+ Restore+Mfg |
| 2E | Find Parallel Ports |
Cold+Warm+ Restore+Mfg |
| 68 | CSET AFT OPROM |
Cold+Warm+ Restore+Mfg |
| BF | Get MC Data | Cold+Warm+ Restore |
| 69 | PCI Configure | Cold+Warm+ Restore+Mfg |
| 6A | MFG Hook 65 | MFG |
| 6B | Init Time Of Day |
Cold+Warm+ Restore+Mfg+ SAD |
| 6C | Check For Locked Key Board | Cold+Warm+ Restore+SAD |
| 6D | Init Enable NMI | Cold+Warm+ Restore+Mfg+ SAD |
| 6E | Set Boot Speed | Cold+Warm+ Restore+Mfg |
| 6F | Set Key Board LEDs |
Cold+Warm+SAD |
| 71 | Init Flush Key Board | Cold+Warm+ Restore+SAD |
| 72 | Move Error Log To EBDA |
Cold+Warm+ Restore+Mfg |
| 73 | Init Disable Mouse | Cold+Warm+ Restore+Mfg+ SAD |
| 74 | Sys Reset | MFG |
| 75 | Phase 2 Exit Big Real | Cold+Warm+ Restore+Mfg+ SAD |
| 76 | BOOT STRAP 1 | Cold+Warm+MFG+SAD |
| 78 | SAD BOOT PROC | SAD |
| 79 | Start Boot Sequence |
N/A |
| 7A | Read Boot Sector | N.A |
| 7B | Boot Sector Read Complete | N.A |
| 7C | Check for CE Boot Override |
N.A |
| 7F | Xfer to boot code |
N.A |
The following codes also produce a series of beeps. The series of beeps are listed for each code followed by an explanation of the code.
| CP Code | Beeps | Definition |
| 82 | 1-1-3 | CMOS write /read failure |
| 83 | 1-1-4 | BIOS ROM checksum failure |
| 84 | 1-2-1 | Programmable Interval Timer test failure |
| 85 | 1-2-2 | DMA initialization failure |
| 86 | 1-2-3 | DMA page register write/read test failure |
| 87 | 1-2-4 | RAM refresh verification failure |
| 88 | 1-3-1 | 1st 64K RAM test failure |
| 89 | 1-3-2 | 1st 64K RAM parity test failure |
| 90 | 2-1-1 | Slave DMA register test in-progress or failure |
| 91 | 2-1-2 | Master DMA register test in-progress or failure |
| 92 | 2-1-3 | Master interrupt mask register test failure |
| 93 | 2-1-4 | Slave interrupt mask register test failure |
| 95 | 2-2-2 | Key-board controller test failure |
| 99 | 2-3-2 | Screen memory test in-progress or failure |
| 9A | 2-3-3 | Screen retrace tests in-progress or failure |
| 9B | N/A | Search for video ROM in-progress |
| 9C | N/A | Screen believed operable - mode in low two bits |
| 9D | N/A | Screen believed operable - mode in low two bits |
| 9E | N/A | Screen believed operable - mode in low two bits |
| 9F | N/A | Screen believed operable - mode in low two bits |
| A0 | 3-1-1 | Timer tick interrupt test failure |
| A1 | 3-1-2 | Interval timer channel 2 test failure |
| A3 | 3-1-4 | Time-Of-Day clock test failure |
| A7 | 3-2-4 | Comparing CMOS memory size against actual |
| A8 | 3-3-1 | Memory size mismatch occurred |
| D0 | N/A | Cache State |
| D1 | N/A | Cache Init |
| D2 | N/A | Cache Restore |
| D3 | N/A | Cache Config |
| D4 | N/A | Cache Flush |
| D5 | N/A | Cache Enable |
| D6 | N/A | Cache Disable |
| D7 | N/A | Cache Custom |
| e1h | N/A | CSET BFR VIDROM |
| e5h | N/A | CSET AFT CMCFG |
Document Location