This document provides information about checking the IBM AnyNet configuration parameters.

Resolving The Problem

=============================================================================
Important Note: Starting in i 7.1, AnyNet (a method used to run SNA communications traffic over IP) is no longer supported. Users of AnyNet are encouraged to migrate to Enterprise Extender as a replacement. For information about migrating to Enterprise Extender from AnyNet, see the Migrating from AnyNet to Enterprise Extender topic in the IBM i Information Center.
=============================================================================

To check the IBM AnyNet configuration parameters, do the following:

1.Ensure the controller description (CTLD) has the following two fields:

o Remote Control Point Name - This must be unique throughout the entire network.
o Remote Network ID - This has to match the following things:
- Local Network ID of the remote system.
- Network ID portion of the Host Table (CFGTCP, Option 10).
2.On the local system, the remote configuration list entry must point to the CTLD that points at the target. On the remote system, the remote configuration list entry must point to the CTLD that points at the source.

Configuration Example

Note: These are just sample names.

Network Attributes (DSPNETA)


System A System B
  • APPN1 Local Net ID Appn2
  • AS400A LOCLOCNAME AS400B


Host Table Entries (CFGTCP, Option 10) (Entry Points to Remote System)
System ASystem B
AS400B.APPN2.SNA.IBM.COMAS400A.APPN1.SNA.IBM.COM
Host.Netid.sna.ibm.comHost.Netid.sna.ibm.com

APPC Controller Description
System A
System B
TCPIP2RMTCPNAMETCPIP1
APPN2RMTNETIDAPPN1

Remote Configuration List
System A
System B
AS400BRMTLOCNAMEAS400A
APPN2RMTNETIDAPPN1
AS400ALOCLOCNAMEAS400B
TCPIP2RMTCPNAMETCPIP1
APPN2RMTCPNETIDAPPN1

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"6.1.0"}]

Historical Number

23794802

Document Information

More support for:
IBM i

Software version:
6.1.0

Operating system(s):
IBM i

Document number:
641001

Modified date:
18 December 2019

UID

nas8N1017303

Manage My Notification Subscriptions