IBM Support

Cannot update HDD firmware on second node - IBM Servers

Troubleshooting


Problem

When attempting to use the IBM SAS hard drive update program on a two-node System x3950 M2 system, the following errors are displayed: "The IBM Hard Drive Update Program detected possible non-warranted hard disk drives in your system. The following screens will help you identify the non-warranted drives and log file (unsupp.log) will be created. These drives have not been recognized as an IBM qualified and warranted part. Firmware updates will not be applied to these drives." Selecting OK to the "Do youwant to identify non-warranted drives" dialog brings up the following: Error detected identifying drive P\N: LSI INT S\N: E 3000 Ada : Chn: SID: Lun:n-W After canceling past this, the update application is only able to identify and update the four harddisk drives in the Primary Node. The hard disk drives in the secondary node do not appear.

Resolving The Problem

Source

RETAIN tip: H194163

Symptom

When attempting to use the IBM SAS hard drive update program on a two-node System x3950 M2 system, the following errors are displayed:

  "The IBM Hard Drive Update Program detected possible non-warranted hard disk drives in your system. The following screens will help you identify the non-warranted drives and log file (unsupp.log) will be created. These drives have not been recognized as an IBM qualified and warranted part. Firmware updates will not be applied to these drives."

Selecting OK to the "Do you want to identify non-warranted drives" dialog brings up the following:

  Error detected identifying drive P\N: LSI INT S\N: E 3000 Ada : Chn: SID: Lun:n-W

After canceling past this, the update application is only able to identify and update the four hard disk drives in the Primary Node. The hard disk drives in the secondary node do not appear.

Affected configurations

The system may be any of the following IBM servers:

  • System x3850 M2, type 7233, any model
  • System x3850 M2, type 7234, any model
  • System x3950 M2, type 7233, any model
  • System x3950 M2, type 7234, any model

This tip is not option specific.

The HDD update utility is affected.

This tip is not Operating System specific.

Solution

A fix will be in the next version of the IBM SAS hard drive update program.

The target date is scheduled for fourth quarter 2008.

The file is available at the following web site:

  http://www.ibm.com/support/docview.wss?uid=psg1MIGR-62832

Workaround

Separate the system into single node partitions and update the hard disk drive firmware on each node individually.

Additional information

The next hard disk drive update program with the fix has a tentative version number of 1.03. The version number is subject to change.

Document Location

Worldwide

Operating System

System x:Operating system independent / None

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW332","label":"System x->System x3850 M2"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW333","label":"System x->System x3950 M2"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
29 January 2019

UID

ibm1MIGR-5078254