Problem

When the path of an IBM Integration Designer workspace contains a space, exceptions can be found in the Problems view and in the log file when adding an external service.

Symptom

The following exceptions can be found in the Problems view and in the log file:

CWSCA8055E: An error occurred while generating the following artifact: WrappedException: MetadataException: Could not load the databinding generator, invalid generator specified on the dataBindingType

CWSCA8057E: An error occurred while the data binding was being generated: Could not load the databinding generator, invalid generator specified on the dataBindingType

Resolving The Problem

You should create a new workspace with no spaces. This will resolve the issue and the new project can then be created and built successfully.