How can the 5250 Telnet Signon screen be bypassed?
Resolving The Problem
To enable bypass sign-on, the following is required:
| o | On the operating system command line, type the following: WRKSYSVAL QRMTSIGN Press the Enter key. Change the value to *VERIFY. |
| o | In the IBM i Access for Windows PC5250 Emulator session: Select Communications, Configure, and then the Advanced option on the left side; select the Bypass Signon option The Bypass sign-on is now enabled. The change will take effect immediately. |
[{"Type":"MASTER","Line of Business":{"code":"LOB68","label":"Power HW"},"Business Unit":{"code":"BU070","label":"IBM Infrastructure"},"Product":{"code":"SWG60","label":"IBM i"},"ARM Category":[{"code":"a8m0z0000000CU9AAM","label":"IBM i Access-\u003EAccess for Windows"}],"ARM Case Number":"","Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.1.0"}]