Broadcom onboard Network Interface Controller port is disabled by Cisco Catalyst Switch Module 3012 - IBM BladeCenter

Troubleshooting


Problem

Systems with on-board NetXtreme I adapters connected to Cisco 3012 Ethernet Switch Modules (ESMs) may have their switch port error disabled by the ESM during Windows shutdown. This condition may also occur when disabling the Network Interface Controller(NIC) from within Windows. The following link-flap error message may be observed in the ESM log by entering "show logging" Cisco Command Line Interface (CLI) command: %PM-4-ERR_DISABLE: link-flap error detected on Gi0/14, putting Gi0/14 in err-disable state

Resolving The Problem

Source

RETAIN tip: H196074

Symptom

Systems configured with on-board NetXtreme I adapters connected to Cisco 3012 Ethernet Switch Modules (ESMs) may have their switch port error disabled by the ESM during Windows shutdown. This condition may also occur when disabling the Network Interface Controller (NIC) from within Windows.

The following link-flap error message may be observed in the ESM log by entering "show logging" Cisco Command Line Interface (CLI) command:

  %PM-4-ERR_DISABLE: link-flap error detected on Gi0/14, putting Gi0/14 in err-disable state

Affected configurations

The system may be any of the following IBM servers:

  • BladeCenter LS20, type 8850, any model
  • BladeCenter HS12, type 8014, any model
  • BladeCenter HS12, type 8028, any model
  • BladeCenter HS20, type 8678, any model
  • BladeCenter HS20, type 8832, any model

The system is configured with at least one of the following:

  • Microsoft Windows 2000 Server, any service pack
  • Microsoft Windows 2003 Server, any service pack

The system is configured with one or more of the following IBM Options:

  • Cisco Catalyst Switch Module 3012 for IBM BladeCenter, Option part number 43W4395

Note: This does not imply that the network operating system will work under all combinations of hardware and software.

Please see the compatibility page for more information: http://www.ibm.com/servers/eserver/serverproven/compat/us/

Solution

This problem is resolved by Broadcom NetXtreme device driver version 12.2.1.2 or software CD version 12.2.4.2 9or later).

The referenced file is available from the "Broadcom NetXtreme Gigabit Ethernet Drivers and Software CD v12.2.4.2 - IBM System x and BladeCenter" web page, at the following URL:

Workaround

As an interim solution, "err-disabled" port can be reset by selecting "disable" then "enable" from Cisco ESM's GUI, or by running the "shutdown", then "no shutdown" commands in the Cisco Intelligent Gigabit Ethernet Switch Module Command Line Interface.

Additional information

Before driver version 12.2.1.2, the driver performed a hard reset on the on-board NIC during Windows shutdown. Sometimes this would lead to frequent link state changes that the ESM would interpret as link flapping. The ESM would deactivate the corresponding port as a result.

With driver version 12.2.1.2, the driver performs a soft reset of Rx CPU on the NIC instead of hard resetting, to eliminate unnecessary link state changes.

Document Location

Worldwide

Operating System

BladeCenter:Windows 2000

BladeCenter:Windows Server 2003

BladeCenter:Windows Server 2003 x86-64

BladeCenter:Windows Server 2003 Datacenter Edition

BladeCenter:Windows Server 2003 Datacenter Edition x86-64

[{"Type":"HW","Business Unit":{"code":"BU056","label":"Miscellaneous"},"Product":{"code":"HW19V","label":"BladeCenter HS20"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"LOB18","label":"Miscellaneous LOB"}},{"Type":"HW","Business Unit":{"code":"BU056","label":"Miscellaneous"},"Product":{"code":"HW19V","label":"BladeCenter HS20"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"LOB18","label":"Miscellaneous LOB"}},{"Type":"HW","Business Unit":{"code":"BU056","label":"Miscellaneous"},"Product":{"code":"HW22K","label":"BladeCenter HS12"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"LOB18","label":"Miscellaneous LOB"}},{"Type":"HW","Business Unit":{"code":"BU056","label":"Miscellaneous"},"Product":{"code":"HW22K","label":"BladeCenter HS12"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"LOB18","label":"Miscellaneous LOB"}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW21G","label":"BladeCenter LS20"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}}]