A fix is available
APAR status
Closed as new function.
Error description
IOCP Update
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: IOCP users requiring support for the * * 9175 IBM z17 model ME1 server and the IBM * * LinuxONE Emperor 5 model ML1. * **************************************************************** * PROBLEM DESCRIPTION: IOCP New Function * **************************************************************** * RECOMMENDATION: APPLY PTF * **************************************************************** This PTF introduces a new release of ICP IOCP and is VERSION 7 RELEASE 1 LEVEL 2 (7.1.2) of the program. ICP IOCP supports the IBM z17 9175 model ME1 and the IBM LinuxONE Emperor 5 model ML1.
Problem conclusion
Temporary fix
FOR RELEASE ES-CMS-740-BASE : PREREQ: VM66902 VM66827 CO-REQ: NONE IF-REQ: NONE
Comments
PROBLEM CONCLUSION: * ICP IOCP VERSION 7 RELEASE 1 LEVEL 2 (7.1.2) provides the following support: - The 9175 models support the following increased coupling limits: - A maximum of 8 CHPIDs per port for TYPE=CL5 and TYPE=CL6 PCHIDs and TYPE=CS5 AIDs. - A maximum of 64 TYPE=CL5 and TYPE=CL6 PCHIDs. - A maximum of 512 coupling CHPIDs which include channel path types: CL5, CL6, CS5, and ICP. * * Documentation Changes: There is a new publication "Input/Output Configuration Program User's Guide for ICP IOCP" which has order number SB10-7183-00. The publication is available at https://www.ibm.com/docs/en/systems-hardware/zsystems by selecting the appropriate IBM Z model and then section Library Overview. * EC (Engineering Change) Information: This PTF level of ICP IOCP contains support for IBM z17 central processor complexes (CPCs). See Usage Notes for further information. * Information on equivalent STAND-ALONE IOCP, z/OS IOCP, and z/VM IOCP follows: * * - Equivalent STAND-ALONE IOCP for ICP IOCP version 7.1.0 is in the listed EC's. The EC's listed are the first levels shipped with this release of IOCP. EC MACHINE TYPE P30924.007 9175 * - Equivalent z/OS and z/VM IOCP is shipped via the listed APARs. OPERATING SYSTEM APAR z/OS OA67614 z/VM 7.3 VM66898 z/VM 7.4 VM66899 * * The EC level of the CPC can be determined from the Hardware Management Console or Support Element by doing the following: 1. From Navigation pane, select 'Systems Management' on HMC or 'System Management' on Support Element. 2. Select 'Systems' on HMC. 3. Select the CPC you are interested in. 4. Expand the 'Change Management' tasks area. 5. Open 'System Information' in the 'Change Management' tasks area and look for Description 'Input/Output Configuration Program' to identify the appropriate EC level. * The STAND-ALONE IOCP version and release can be determined by looking at the header lines of the IOCP reports produced by STAND-ALONE IOCP. The STAND-ALONE IOCP version and release can also be found in IOCP message ICP073I in an I/O Configuration Source file that was processed by STAND-ALONE IOCP. The STAND-ALONE IOCP version and release can also be determined from the Hardware Management Console or Support Element by doing the following (begin with step 6 for the Support Element Console): 1. Select 'Systems Management' from Navigation pane. 2. Select 'Systems'. 3. Select the CPC you are interested in. 4. Expand the 'Recovery' tasks area. 5. Open 'Single Object Operations' in the 'Recovery' tasks area to connect to the Support Element. 6. Select 'System Management' from Navigation pane. 7. Select the CPC or an activated partition. (Note that an activated partition is required to write an IOCDS.) 8. Expand 'Configuration' from the tasks area. 9. Open 'Input/output (I/O) Configuration' in the 'Configuration' tasks area. 10. Select 'View' pull-down. 11. Select 'Configuration Program Level'. * Usage Notes: 1. If you are currently using a release of ICP IOCP and you do not plan on upgrading to the listed EC level, you can still install this PTF and replace your existing ICP IOCP. The 2827, 2828, 2964, 2965, 3906, 3907, 8561, 8562, 3931, and 3932 models can power-on reset with an IOCDS written by the ICP IOCP shipped by this PTF. Also, the 2827, 2828, 2964, 2965, 3906, 3907, 8561, 8562, 3931, and 3932 models can still power-on reset with an IOCDS that was written by your previous release of ICP IOCP. There is no requirement that you write an IOCDS with the ICP IOCP shipped by this PTF and perform a power-on reset after the PTF has been installed. 2. If you are currently using a release of ICP IOCP for a 9175 model but do not plan on upgrading to the listed EC level, you can still install this PTF and replace your existing ICP IOCP. There is no requirement that you write an IOCDS with the ICP IOCP shipped by this PTF and perform a power-on reset after the PTF has been installed. 3. Any IOCDS previously created by an ICP version of IOCP (z/OS, VM, VSE, or STAND-ALONE) can be reported on by the ICP version of IOCP shipped by this PTF. 4. Any IOCDS previously created by another version of IOCP (e.g. IYP IOCP) cannot be reported on by the ICP version of IOCP shipped by this PTF or by the STAND-ALONE equivalent version of the ICP IOCP program. (For HCD users, HCD manages the correlation of IOCP versions to CPC model for you.) 5. If you are upgrading to a 9175 model, you MUST write a 9175 IOCDS to your current 8561 or 3931 CPC as described here or write a 9175 IOCDS after the upgrade is completed. Prior to the upgrade, use IOCP execution parameter CHECKCPC=NO or HCD option 'Write IOCDS in preparation of upgrade'. The IOCDS will be unusable until your CPC has been upgraded to a 9175. Inform the installing service representative that you have pre-written a 9175 IOCDS and which IOCDS should be selected after the upgrade. KEYWORDS: R9175/K D/T9175
APAR Information
APAR number
VM66899
Reported component name
VM CMS
Reported component ID
568411201
Reported release
740
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-11-11
Closed date
2025-12-17
Last modified date
2025-12-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UM90579
Modules/Macros
DMSICP DMSINL DMSLVLTB ICPCARDF ICPCARDS ICPCARDU ICPCARDW ICPCARDX ICPCARDY ICPCARDZ ICPCFRST ICPCGET ICPCGNDS ICPCINIT ICPCIOCP ICPCIOCU ICPCIODV ICPCMSG ICPCPCHK ICPCPUT ICPCRDDS ICPCRPT ICPCRPTA ICPCRPTB ICPCRPTF ICPCRPTX ICPCRTNS ICPCRTNX ICPCWTDS ICPLIM ICPPCNTL ICPPVM 7VMCMS40
| SB10718300 |
Fix information
Fixed component name
VM CMS
Fixed component ID
568411201
Applicable component levels
R740 PSY UM90579
UP25/12/17 I 1000
Fix is available