A fix is available
APAR status
Closed as program error.
Error description
When VM66812 is applied in an SSI FORCE ARCH is still required for relocations.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All users of Live Guest Relocation * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: APPLY PTF * **************************************************************** Customers applying VM66812 APAR across an SSI would eventually need to issue FORCE ARCH relocations to move virtual machines from systems without the APAR applied back to systems that do have VM66812 applied. The problem was caused by the changing of an internal system value (SYSMAXD) between processors.
Problem conclusion
The default architectural value of interest will be restored to the previous value, repairing functionality for relocations to systems which had VM66812 applied.
Temporary fix
FOR RELEASE VM/ESA CP/ESA R720 : PREREQ: VM66812 CO-REQ: NONE IF-REQ: NONE FOR RELEASE VM/ESA CP/ESA R730 : PREREQ: VM66812 CO-REQ: NONE IF-REQ: NONE
Comments
APAR Information
APAR number
VM66832
Reported component name
VM CP CP
Reported component ID
568411202
Reported release
720
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-03-11
Closed date
2025-03-31
Last modified date
2025-07-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UM90513 UM90514
Modules/Macros
HCPZCP
Fix information
Fixed component name
VM CP CP
Fixed component ID
568411202
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SG27M","label":"APARs - z\/VM Environment"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Line of Business":{"code":"LOB16","label":"Mainframe HW"}}]
Document Information
Modified date: