A fix is available
APAR status
Closed as new function.
Error description
This APAR contains required service for z/VM version 7 release 4.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users who need to capture I/O trace data for * * devices in alternate subchannel sets * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: APPLY PTF * **************************************************************** TRSOURCE IO 5-digit Device Support ---------------------------------- TRSOURCE currently supports 4-digit addresses for IO tracing. This item extends the support to 5-digit device addresses, which comprise a subchannel-set (SS) number concatenated to the left of the device address. The TRACERED MODULE will similarly to TRSOURCE be updated to properly format I/O trace data including the potential 5th digit. Refer to the CP Commands and Utilities Reference for more information about the changes to the TRACERED utility.
Problem conclusion
Temporary fix
FOR RELEASE ES-DVF-740 : PREREQ: NONE CO-REQ: NONE IF-REQ: UM90510(VM66829-7VMCPR40)
Comments
TRSOURCE IO 5-digit Device Support ---------------------------------- TRACERED MODULE was updated to process and format I/O trace data which includes the new 5th digit of the real device address.
APAR Information
APAR number
VM66830
Reported component name
ESA DVF
Reported component ID
568411208
Reported release
740
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2025-02-25
Closed date
2025-03-31
Last modified date
2025-09-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UM90515
Modules/Macros
HCSFRI 7VMDVF40
| SC24626874 |
Fix information
Fixed component name
ESA DVF
Fixed component ID
568411208
Applicable component levels
R740 PSY UM90515
UP25/04/03 P 2502
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SG27M","label":"APARs - z\/VM Environment"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"740","Line of Business":{"code":"LOB16","label":"Mainframe HW"}}]
Document Information
Modified date: