A fix is available
APAR status
Closed as new function.
Error description
Wait state 9030 during IPL of z/VM on newer machines
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All z/VM users * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: APPLY PTF * **************************************************************** The testing for feature bits at IPL time needs to be revised to avoid wait state 9030 on new machines.
Problem conclusion
Temporary fix
FOR RELEASE VM/ESA CP/ESA R640 : PREREQ: NONE CO-REQ: NONE IF-REQ: NONE
Comments
Feature bit testing in HCPRFI has been changed to allow IPL on all machines supported by z/VM 6.4.
APAR Information
APAR number
VM65980
Reported component name
VM CP
Reported component ID
568411202
Reported release
640
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2017-01-31
Closed date
2017-02-24
Last modified date
2017-04-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UM35049
Modules/Macros
HCPRFI
Fix information
Fixed component name
VM CP
Fixed component ID
568411202
Applicable component levels
R640 PSY UM35049
UP17/02/24 P 1701
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG27M","label":"APARs - z\/VM environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Edition":"","Line of Business":{"code":"LOB16","label":"Mainframe HW"}}]
Document Information
Modified date: