HASM-HA-INCORROUT MISCELLANEOUS FIXES TO IBM I POWERHA

Error Description

The following fixes are included:                              
* The DSPCRGINF command may show incorrect node status when    
clustering is inactive on the node the command is run from.    
* CHGCRGPRI may complete successfully without switching the IASP
if the CRG recovery domain contains a node with a role of      
*REPLICATE.                                                    
* DSPSVCSSN displays a diagnostic message for Global Mirror    
sessions that may have inaccurate estimated information in the  
message.                                                        

Problem Summary

The following fixes are included:                              
* The DSPCRGINF command may show incorrect node status when    
clustering is inactive on the node the command is run from.    
* CHGCRGPRI may complete successfully without switching the IASP
if the CRG recovery domain contains a node with a role of      
*REPLICATE.                                                    
* DSPSVCSSN displays a diagnostic message for Global Mirror    
sessions that may have inaccurate estimated information in the  
message.                                                        

Problem Conclusion

The following fixes are included:                              
Problem: The DSPCRGINF command may show incorrect node status  
when clustering is inactive on the node the command is run from.
Resolution: The DSPCRGINF command has been corrected to show    
inactive and unknown node statuses when clustering is inactive  
on the node the command is being run from.                      
                                                               
Problem: CHGCRGPRI may complete successfully without switching  
the IASP if the CRG recovery domain contains a node with a role
of *REPLICATE.                                                  
Resolution: CHGCRGPRI has been corrected to properly switch when
a node with a role of *REPLICATE is in the recovery domain of  
the CRG.                                                        
                                                               
Problem: DSPSVCSSN displays a diagnostic message for Global    
Mirror sessions that may have inaccurate estimated information  
in the message.                                                
Resolution: The diagnostic message for SVC Global Mirror        
sessions has been improved.                                    

Temporary Fix

Comments

Circumvention


PTFs Available

R710 SI66983 PTF Cover Letter   1000
R720 SI67129 PTF Cover Letter   8249

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 5770HAS00
Failing Module.......................... RCHMGR
Reported Release................... R710
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.2.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0;V7R2M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
13 September 2018