IBM Support

SE68346 - OSP-OTHER-MSGCPFBB22 PARAMETERS PASSED DURING CHGCLUMON THAT
ARE NOT ACCURATE CAN CAUSE FAILOVER TO TRIGGER.

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 APAR (Authorized Program Analysis Report)

Abstract

OSP-OTHER-MSGCPFBB22 PARAMETERS PASSED DURING CHGCLUMON THAT
ARE NOT ACCURATE CAN CAUSE FAILOVER TO TRIGGER.

Error Description

There may be an issue when performing a CHGCLUMON where if all  
of the parameters are not being entered absolutely correct, it  
could cause a code path check to fail and subsequently trigger  
a failure to cluster which sets off failover events and varies  
off the IASP.                                                  

Problem Summary

There may be an issue when performing a CHGCLUMON where if all  
of the parameters are not being entered absolutely correct, it  
could cause a code path check to fail and subsequently trigger a
failure to cluster which sets off failover events and varies off
the IASP.                                                      

Problem Conclusion

The CHGCLUMON error path was not being initialized correctly,  
which is now corrected.                                        

Temporary Fix

Comments

Circumvention


PTFs Available

R710 SI66971 PTF Cover Letter   1000
R720 SI66220 PTF Cover Letter   8032
R730 SI66222 PTF Cover Letter   8025

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 5770SS100
Failing Module.......................... RCHMGR
Reported Release................... R720
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.2.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0;V7R2M0;V7R3M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: