Error description

  • After upgrade to MQ v8, Partial Repository's cluster sender
    channels occasionally get stuck in status INITIALIZING and do
    not transition to RUNNING.
    
    Ending and restarting the channel results in initializing again.
    
    Manager's log will show AMQ9514 Channel in use.
    
    Full repositories can experience this problem also.
    

Local fix

  • End and restart the Queue Manager. Consider changing the
    channel inactivity timeout to 0 to avoid after restart.
    

Problem summary

  • After upgrade to MQ v8, Partial Repository's cluster sender
    channels occasionally get stuck in status INITIALIZING and do
    not transition to RUNNING.
    
    Ending and restarting the channel results in initializing again.
    
    Manager's log will show AMQ9514 Channel in use.
    
    Full repositories can experience this problem also.
    

Problem conclusion

  • IBM MQ code will be modified to better track active CLUSSDR
    channels
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v8.0       8.0.0.9
    v9.0 CD    9.0.5
    v9.0 LTS   9.0.0.3
    
    
    The latest available maintenance can be obtained from
    'WebSphere MQ Recommended Fixes'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037
    
    If the maintenance level is not yet available information on
    its planned availability can be found in 'WebSphere MQ
    Planned Maintenance Release Dates'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    SE68262

  • Reported component name

    IBM MQ ISERIES

  • Reported component ID

    5724H7254

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-10-17

  • Closed date

    2017-11-29

  • Last modified date

    2020-01-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    IBM MQ ISERIES

  • Fixed component ID

    5724H7254

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSYHRD","label":"IBM MQ"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]

Document Information

Modified date:
02 January 2020