  • Closed as program error.

Error description

  • Customer complained incorrect message AMQ8023 on MQ IBM i
    environment.  When they execute RSTMQMCHL then they receive
    AMQ8023 with incorrect reset value zero on job log. However, in
    the qmgr's AMQERR01.LOG, that  AMQ8023 message is recorded with
    correct value.
    
    Recreate steps:
    - RSTMQMCHL CHLNAME(SYSTEM.DEF.SENDER) MQMNAME(QmgrName)
    - Reviewed the joblog, we find
    'new sequence number of the channel is 0'.   <=== incorrect.
    - Reviewed the Qmgr's AMQERR01.LOG, we find the
     'new sequence number of the channel is 1'.   <=== correct.
    
    The issue is applicable for other MQ versions,such as MQ IBM i
    Version 8, 7.1 etc.
    
    <<Example>>
    <JOBLOG>
    *NONE      Request                      17/09/15
    04:53:40.078855
      QPTCHECK                 *N       QUICMD      QSYS
    0543
    Message . . . . :  -RSTMQMCHL CHLNAME(SYSTEM.DEF.SENDER)
    MQMNAME(QMGR1)
    AMQ8023    Completion              00   17/09/15
    04:53:44.972764
      LIBMQMSG     QMQM        *STMT    QUIMNDRV    QSYS
    0608
      From module . . . . . . . . :   AMQOCSMX
      From procedure  . . . . . . :   ocmSendCompMsg
      Statement . . . . . . . . . :   1
      Message . . . . :   IBM MQ channel reset.
      Cause . . . . . :   Channel 'SYSTEM.DEF.SENDER' has been
    reset,
      the new sequence number of the channel is 0.
      Recovery  . . . :   None.
      Technical Description . . . . . . . . :   None.
    
    <Qmgr's AMQERR01.LOG>
          .
    17/09/15 04:53:44 - Process(177.104) User(QMQM)
                        Jobname(107097/QMQM/AMQZLAA0  )
    
                        Host(TEST1.IBM.COM)
                        VRMF(9.0.0.1) QMgr(QMGR1)
    
    AMQ8023: IBM MQ channel reset.
    
    Explanation :
    
    Cause . . . . . :
    
    Channel 'SYSTEM.DEF.SENDER' has been reset, the new sequence
    number of
    the channel is 1.
    
    Recovery  . . . :  none
    
    Technical Description . . . . . . . . :   None.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Users who use RSTMQMCHL command to reset message sequence
    number.
    
    
    Platforms affected:
    IBM iSeries
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    The IBM i job log doesn't show the new sequence number
    correctly. It always shows 0.
    

Problem conclusion

  • MQ code is changed to make IBM i joblog show the new sequence
    number correctly.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v8.0       8.0.0.9
    v9.0 CD    9.0.5
    v9.0 LTS   9.0.0.3
    
    The latest available maintenance can be obtained from
    'WebSphere MQ Recommended Fixes'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037
    
    If the maintenance level is not yet available information on
    its planned availability can be found in 'WebSphere MQ
    Planned Maintenance Release Dates'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    SE68188

  • Reported component name

    IBM MQ ISERIES

  • Reported component ID

    5724H7264

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-10-03

  • Closed date

    2017-10-23

  • Last modified date

    2018-04-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    IBM MQ ISERIES

  • Fixed component ID

    5724H7264

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSYHRD","label":"IBM MQ"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]

Document Information

Modified date:
10 April 2018