Abstract

INCORROUT-DSPASPSTS INCORRECT CURRENT TIME IF COMPLETE BIT NOT
SET DURING SWITCHOVER

Error Description

From v7r1 to v7r2, a new vary "history" feature was introduced  
to DSPASPSTS. This allowed for a history of 64 varies to be    
recorded (with the times for each vary). Via internal testing  
for one of our PTFs it was discovered that during a switchover,
the clustering code was calling an interface that had not been  
updated to be compatible with this new "vary history"          
functionality.                                                  

Problem Summary

From v7r1 to v7r2, a new vary "history" feature was introduced  
to DSPASPSTS. This allowed for a history of 64 varies to be    
recorded (with the times for each vary). Via internal testing  
for one of our PTFs it was discovered that during a switchover,
the clustering code was calling an interface that had not been  
updated to be compatible with this new "vary history"          
functionality.                                                  

Problem Conclusion

The YASP interface that clustering code was changed to be      
compatible with the "vary history" functionality introduced in  
v7r2.                                                          

Temporary Fix

Comments

Circumvention


PTFs Available

R720 SI63560 PTF Cover Letter   7290
R730 SI63561 PTF Cover Letter   7283

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 5770SS100
Failing Module.......................... RCHMGR
Reported Release................... R720
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.3.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R2M0;V7R3M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
28 October 2017