Abstract

OSP-OTHER-LOOP SYSTEM JOBS WILL NOT END.

Error Description

System IASP Jobs are not ending during a Vary Off, but taking  
cpu.  Servicedocs collection shows loop in RmslLockCheck.      
However, further investigation using MSD showed QSPFILES is    
involved in the loop.                                          
So far, we have only seen this symptom on LPARS using IASPs.    

Problem Summary

System IASP Jobs are not ending during a Vary Off, but taking  
cpu.  Servicedocs collection shows loop in RmslLockCheck.      
However, further investigation using MSD showed QSPFILES is    
involved in the loop.                                          
So far, we have only seen this symptom on LPARS using IASPs.    

Problem Conclusion

The IASP vary off code path is changed to ensure that System    
Jobs using IASPs are ended.  This will ensure that System Jobs  
don't get stuck around after the IASP is varied off.            
Vary off will now wait a maximum of 10 minutes for System Jobs  
to end.  If there are system jobs that have not ended, a message
for each job will be output to QSYSOPR once per minute until the
10 minute timeout (or the jobs end).  If the system jobs have  
still not ended by the end of the 10 minutes, the vary off will
continue. The message is CPF9898.                              

Temporary Fix

Comments

Circumvention


PTFs Available

R710 SI60254 PTF Cover Letter   6320
R720 SI60255 PTF Cover Letter   6306
R730 SI60256 PTF Cover Letter   7061

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 5770SS100
Failing Module.......................... RCHMGR
Reported Release................... R710
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.2.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0;V7R2M0;V7R3M0","Edition":"","Line of Business":{"code":"","label":""}}]