Abstract

RDARS-T/QRLCASMAPO-MSGMCH1210 WHEN MARKING AN OPTICAL VOLUME
FULL

Error Description

MCH1210 to QRLCASMAPO module when marking an optical volume    
full.                                                          

Problem Summary

Message MCH1210 was issued by module QRLCASMAPO when marking an
optical volume full.                                            
                                                               
The Start Archived Storage Management (STRASMOND) command will  
start the instance server if it is not active so that it can    
archive the reports it generates to the Content Manager OnDemand
system log.  This can result in the instance server remaining up
after the reports are archived when it had been previously      
ended.                                                          
                                                               
When message OND0519 is issued it does not format correctly.    
                                                               
When using optical the bytes used might be calculated          
incorrectly.                                                    

Problem Conclusion

The optical volume capacity in table QARLCOVET is 15 digits.    
The code only allowed for 11 digits.  The code will now handle a
capacity greater than 11 digits.                                
                                                               
The Start Archived Storage Management (STRASMOND) command will  
now end the instance server if it starts it, thereby returning  
the instance server to its original state.                      
                                                               
Message OND0519 will now format correctly.                      
                                                               
There was a rare case where the optical bytes used might be    
calculated incorrectly.  This has been fixed.  This could cause
a volume to be marked full that was not actually full.  You can
run the following command to reset the optical bytes used if    
necessary.  CALL PGM(QRDARS/QRLCASMROV) PARM('instance name')  
replacing 'instance name' with the name of an instance.  This  
process will not automatically reset the optical volume full    
flag of a volume if it is set to yes.  It is a manual process to
reset any optical volume that might have been marked full in    
error.                                                          

Temporary Fix

Comments

Circumvention


PTFs Available

R710 SI59888 PTF Cover Letter   6320

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 5770RD100
Failing Module.......................... RCHMGR
Reported Release................... R730
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.3.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0;V7R3M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 December 2016