IBM Support

SE61165: In RDI 9.1.0 Screen Designer with multiple WDWTITLE keywords in record, only first parameters recognized/others ignored(24843)

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When using Screen Designer in IBM Rational Developer for i 9.1.0
    and 9.1.1 to display screen titles in a display file, dspf, with
    multiple WDWTITLE parameters only the first parameters are
    allowed and others are ignored.
    
    If ITEM MASTER ADDITIONAL DETAILS is the title and is set to
    *LEFT with no top indicated and
    F8=UPDATE is set to *LEFT *BOTTOM.
    ITEM MASTER ADDITIONAL DETAILS should be in the top left border.
    However, the emulator and design and screen panels take the
    *LEFT only and ignore any others.
    The IBM i documentation reads:
    #1 If you specify the WDWTITLE keyword more than once at the
    effect are combined.
    #2 The *TOP/*BOTTOM parameter specifies if the text should be
    embedded in the top or bottom border.  If not specified, the
    text will be placed in the top border.
    
    In #1 combining *LEFT and *BOTTOM would result in *LEFT and
    *BOTTOM.
    In #2, *LEFT has no accompanying *TOP or *BOTTOM parameter and
    so should result in *LEFT and *TOP, but are ignored.
    
    The emulator and preview and design panes will be reviewed
    to match the WDWTITLE specifications.
    

Local fix

  • Manually add the *TOP in the design panes or in the dspf code
    for the title to be set in the top border.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * DDS developers using RDi.                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * In RDi Screen Designer WDWTITLEs were not shown in the top   *
    * and bottom at the same time.                                 *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    DDS allows WDWTITLEs to be specified concurrently for both the
    top and bottom rows of a window.  Screen Designer would only
    show the title in either the top or bottom in both the Design
    Page and Preview Page.  The size of the title was not being
    truncated in the Preview page.  The bracketing attribute bytes
    were not being displayed correctly in the Design Page.
    

Problem conclusion

  • This problem is fixed in the RDi 9.5.0.3 update.
    

Temporary fix

Comments

APAR Information

  • APAR number

    SE61165

  • Reported component name

    RATL DEV FOR I

  • Reported component ID

    5724Y99DI

  • Reported release

    910

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-01-27

  • Closed date

    2016-04-22

  • Last modified date

    2016-04-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • Designer
    

Fix information

  • Fixed component name

    RATL DEV FOR I

  • Fixed component ID

    5724Y99DI

Applicable component levels

  • R910 PSY

       UP

  • R911 PSY

       UP

  • R950 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAE4W","label":"Rational Developer for i"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.1","Line of Business":{"code":"LOB57","label":"Power"}}]

Document Information

Modified date: