TCPIP-INCORROUT IPV6 SUBNET FILTER RULE MAY USE INCORRECT MASK

Error Description

When an IPv6 subnet is defined with a prefix length that's not a
multiple of 8, the prefix length is rounded down to a multiple  
of 8, causing the subnet to reference a larger range of        
addresses than desired.                                        
                                                               
Also, displaying active filter rules through IBM Navigator for i
omits all rules based on an IPv6 range or subnet.              

Problem Summary

When an IPv6 subnet is defined with a prefix length that's not a
multiple of 8, the prefix length is rounded down to a multiple  
of 8, causing the subnet to reference a larger range of        
addresses than desired.                                        
                                                               
Also, displaying active filter rules through IBM Navigator for i
omits all rules based on an IPv6 range or subnet.              

Problem Conclusion

IPv6 prefix length processing by filter rules has been          
corrected. Display of active packet filter rules for IPv6 ranges
and subnets has also been corrected.                            

Temporary Fix

Comments

Circumvention


PTFs Available

R710 SI55095 PTF Cover Letter   5142
R720 SI54986 PTF Cover Letter   5135

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 5770SS100
Failing Module.......................... RCHMGR
Reported Release................... R720
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.2.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0;V7R2M0","Edition":"","Line of Business":{"code":"","label":""}}]