IBM Support

SE55249: INCORRECT ERROR MESSAGE FOR PARM SPECIFICATION WITH RSTD(*YES) AND FIRST VALUES ' '

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • When editing CL source, and using the F4 key to prompt a PARM
    statement, the CL Prompt dialog for the statement shows an error
     message when it shouldn't.
    This occurs for a PARM statment which has a VALUES() parameter
    with a first value of a space in quotes.  (It may be a list of
    values).
    
    Here is an example:
       PARM     ...    VALUES(   ' '    'X'   )
    

Local fix

  • Move ' ' from the first value postion as shown below:
    
    PARM       KWD(DATESE3) TYPE(*CHAR) LEN(1) RSTD(*YES) +
               VALUES('-' ' ' '/' '.')  PROMPT('Date separator')
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Those who edit and prompt CL commands        *
    ****************************************************************
    * PROBLEM DESCRIPTION: CL prompt dialog reports incorrect      *
    *                      error.                                  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This problem is fixed in the RDi 9.0.1 update.
    
    When editing CL source, and using the F4 key to prompt a PARM
    statement, the CL Prompt dialog for the statement shows an
    error message when it shouldn't.
    This occurs for a PARM statement which has a VALUES()
    parameter with a first value of a space in quotes.
    (It may be a list of values)
    eg.   PARM     ...    VALUES(   ' '    'X'   )
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    SE55249

  • Reported component name

    RPG/COBOL DEV T

  • Reported component ID

    5724Y9901

  • Reported release

    850

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-03-19

  • Closed date

    2013-12-11

  • Last modified date

    2013-12-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • R850 PSY

       UP

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SS4QVT","label":"Rational Developer for Power Systems Software"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]