OSP-MSGCPF3763 *MGTCOL objects damaged
Error Description
Intermittently receiving msgcpf3763 Q* in library QMGTC2
previously damaged during backup. APAR created for additional
data collection
Problem Summary
Message CPF3763 was received when trying to save an object of
type *MGTCOL with attribute *PFRDTL or *PFRHST.
Problem Conclusion
*MGTCOL objects with attributes *PFRDTL or *PFRHST can become
damaged when being concurrently updated by both Management
Central Monitors and one of the Management Central jobs
QYMEPFRCVT or QYMEARCPMA. The Management Collection Object code
has been changed to fix this problem. This fix will not correct
any previously damaged objects.
Temporary Fix
Comments
Circumvention
PTFs Available
Affected Modules
Affected Publications
Summary Information
Status............................................ | CLOSED PER |
HIPER........................................... | No |
Component.................................. | 5770SS100 |
Failing Module.......................... | RCHMGR |
Reported Release................... | R710 |
Duplicate Of.............................. |
System i Support
IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information