IBM Support

SE29844 - MQM400 LODPTF OF FIXPACK 6.0.2.2 FAILS WITH AMQ6903

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 APAR (Authorized Program Analysis Report)

Abstract

MQM400 LODPTF OF FIXPACK 6.0.2.2 FAILS WITH AMQ6903

Error Description

If an attempt is made to LODPTF 6.0.2.2 while the queue manager
is active, an AMQ6903 message is posted and the Load fails.    
This is because FP 6.0.2.1 calls a PTF exit program during the  
permanent apply process which checks to see if MQ resources are
active.                                                        
If a FP prior to 6.0.2.1 is applied, this error will not occur.

Problem Summary

LODPTF for WMQ v6.0.2.2 PTFs fails if WMQ subsystem QMQM is    
active; with the following messages in the joblog              
                                                               
Using exit program AMQIPTFX.1.6 for product 5724H72 and PTF    
SI27144                                                        
Subsystem name QMQM active.                                    
Exit program failed and permanent changes have been made.      
PTF 5724H72-SI27144 not applied.                                
                                                               
Users affected: All WMQ v6.0.2.1 users on iSeries Platform who  
attempts to load future WMQ FP/RP PTFs while QMQM subsystem is  
active.                                                        
                                                               
Platforms affected: iSeries                                    
                                                               
During LODPTF with SPRPTF(*APYPERM) the previous PTFs, if      
temporarily applied, becomes permanently applied.              
There was an erroneous check in the PTF exit code path, which  
checks for the QMQM subsystem being active and prevented the    
previous PTFs in temporary applied state to become permanently  
applied, leading to the LODPTF failure.                        

Problem Conclusion

Code changes were carried out in order to remove the check and  
to allow the PTF load to take place even when the QMQM          
subsystem is active.                                            
                                                               
Users with WMQ v6.0.2.1 currently applied temporarily on their  
system will have to end all WMQ queue managers fully and stop  
the QMQM subsystem before loading the PTFs for subsequent WMQ  
FP/RP on v6.                                                    
                                                               
This fix when applied will ensure that users with WMQ PTFs      
applied temporarily will be able to load the PTFs when QMQM    
subsystem is active.                                            
                                                               
Users with a service level earlier than v6.0.2.1 will be able  
to use LODPTF for subsequents levels of WMQ FP/RP with SPRPTF  
(*APYPERM) without experiencing this problem.                  

Temporary Fix

Comments

Circumvention


None                                                            

PTFs Available

R600 SI47898 PTF Cover Letter   1000

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 5724H7206
Failing Module.......................... RCHMGR
Reported Release................... R600
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V6R0M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: