MQM400 STRMQM FAILS WITH AMQ7432 ARCE_LOG_RECD_NOT_FOUND

Error Description

STRMQM fails with AMQ7432 due to rc=arcE_LOGGING_ERROR.        
Probe Id          :- AT013001                                  
Component         :- atmRecoveryIndoubtPass                    
Major Errorcode   :- xecF_E_UNEXPECTED_RC                      
Minor Errorcode   :- arcE_LOG_RECD_NOT_FOUND                    
LSNCode is blank for OLDST timestamp.                          

Problem Summary

STRMQM failed with AMQ7432 along with FDC reporting            
arcE_LOG_RECD_NOT_FOUND. While analysing the situation it was  
realised that further diagnostics will be helpful for such      
situation in future.                                            
                                                               
Very rare happening issue in iSeries where journal records not  
written or retrieved correctly.                                
                                                               
Platforms affected: iSeries                                    
                                                               
At the time of writing to the journal, diagnostic is not        
produced if log sequence number (LSN) generated is not as      
expected. Also it was found that improvement of an existing FDC
to provide further information on the journal replay was        
needed.                                                        

Problem Conclusion

WMQ code changes was carried out to add diagnostics (FDC)      
during writing to the journal if LSN is not as expected. Also  
an existing FDC was improved to provide the required            
information on the journal replay.                              
                                                               
The fix will be included in WMQ 6.0.2.3                        

Temporary Fix

Comments

Circumvention


None                                                            

PTFs Available

R600 SI47898 PTF Cover Letter   1000

Affected Modules

         
         

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 5724H7206
Failing Module.......................... RCHMGR
Reported Release................... R600
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V6R0M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
11 December 2012