Subscribe to this APAR
By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.
APAR (Authorized Program Analysis Report) |
Abstract
MQM400 WRKMQM OPTION 22 RESULTS IN CPF3C53
Error Description
WRKMQM Option 22 results in CPF3C53, Job &3/&2/&1 not found.
It has been determined that when at least one job connected
to the queue manager is 26 characters in length and you
attempt to take option 22 from WRKMQM it will fail with a
CPF3C53.
Problem Summary
****************************************************************
USERS AFFECTED:
Users of MQ version 6 who have job names of 26 characters.
Platforms affected:
iSeries
****************************************************************
PROBLEM SUMMARY:
jobname was an array of 28 chars.
The jobname comes back null terminated within the 28 chars.
However, in this case of a user profile 10 chars in length
resulting in job of 28 chars, the null terminator didn't fit and
hence the strcpy/strtok copied in garbage.
Problem Conclusion
Declared the array of right size.
WRKMQM Option 22 will NOT result in CPF3C53, whatever be the
jobname.
---------------------------------------------------------------
The fix is targeted for delivery in the following PTFs:
v6.0
Platform Fix Pack 6.0.2.1
-------- --------------------
iSeries SI25716
The latest available maintenance can be obtained from
'WebSphere MQ Recommended Fixes'
http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037
If the maintenance level is not yet available, information on
its planned availability can be found in 'WebSphere MQ
Planned Maintenance Release Dates'
http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309
---------------------------------------------------------------
Temporary Fix
Comments
Circumvention
Use Userprofile or Jobnames with less than 10 characters in
length .
PTFs Available
Affected Modules
Affected Publications
Summary Information
Status............................................ | CLOSED PER |
HIPER........................................... | No |
Component.................................. | 5724H7206 |
Failing Module.......................... | RCHMGR |
Reported Release................... | R600 |
Duplicate Of.............................. |
System i Support
IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information