IBM Support

SE23241 - MQM400 STRMQMMQSC fails with -MCH3601 and CEE9901 exception for
*DFT queue manager.

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 APAR (Authorized Program Analysis Report)

Abstract

MQM400 STRMQMMQSC fails with -MCH3601 and CEE9901 exception for
*DFT queue manager.

Error Description

STRMQMMQSC fails with MCH3601 when queue manager name has a    
value of *DFT (STRMQMMQSC MQMNAME(*DFT) ).                      
.                                                              
STRMQMMQSC SRCMBR(MQAS01_Q) SRCFILE(QGPL/QMQSC)                
.                                                              
Pointer not set for location referenced.                        
Application error.  MCH3601 unmonitored by RUNMQSC at statement
  0000000068, instruction X'0000'.                              
Error report generated for MQSC command process.                
Error found on STRMQMMQSC command.                              
.                                                              
......                                                          
Message ID . . . . . . :   MCH3601                              
Message . . . . :   Pointer not set for location referenced.    
From program . . . . . . . . . :   RUNMQSC                      
  From library . . . . . . . . :     QMQM                      
  From module  . . . . . . . . :     AMQUIN00_N                
  From procedure . . . . . . . :     main                      
  From statement . . . . . . . :     68                        
To program . . . . . . . . . . :   RUNMQSC                      
  To library . . . . . . . . . :     QMQM                      
  To module  . . . . . . . . . :     AMQUIN00_N                
  To procedure . . . . . . . . :     main                      
  To statement . . . . . . . . :     68                        
.                                                              
.                                                              
Message ID . . . . . . :   CEE9901                              
Message . . . . :   Application error.  MCH3601 unmonitored by  
RUNMQSC                                                        
at statement 0000000068, instruction X'0000'.                  
From program . . . . . . . . . :   QLEAWI                      
  From library . . . . . . . . :     QSYS                      
  From module  . . . . . . . . :     QLEDEH                    
  From procedure . . . . . . . :     Q LE leDefaultEh          
  From statement . . . . . . . :     168                        
To program . . . . . . . . . . :   AMQOCRMX                    
  To library . . . . . . . . . :     QMQM                      
  To module  . . . . . . . . . :     AMQOCRMX_N                
  To procedure . . . . . . . . :     invoke_non_threaded_target
  To statement . . . . . . . . :     4                          

Problem Summary

****************************************************************
USERS AFFECTED:                                                
All users who use STRMQMQSC command with *DFT as queue manager  
name.                                                          
                                                               
Platforms affected:                                            
iSeries                                                        
****************************************************************
PROBLEM SUMMARY:                                                
Argument(argc and argv) parameters passed from command          
processing Program of CL command STRMQMMQSC to the RUNMQSC      
program was not correct.                                        

Problem Conclusion

The problem has been fixed by checking the values and          
correcting the parameters in RUNMQSC program.                  
                                                               
---------------------------------------------------------------
The fix is targeted for delivery in the following PTFs:        
                                                               
                   v6.0                                        
Platform           Fix Pack 6.0.1.1                            
--------           --------------------                        
iSeries            SI21854                                      
                                                               
The latest available maintenance can be obtained from          
'WebSphere MQ Recommended Fixes'                                
http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037
                                                               
If the maintenance level is not yet available, information on  
its planned availability can be found in 'WebSphere MQ          
Planned Maintenance Release Dates'                              
http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309
---------------------------------------------------------------

Temporary Fix

Comments

Circumvention


Specify the queue manager name for the MQMNAME parameter.      

 For example,                                                  
  STRMQMMQSC SRCMBR(MQAS01_Q) SRCFILE(QGPL/QMQSC)              
MQMNAME(MQAS01)                                                

PTFs Available

R600 SI47898 PTF Cover Letter   1000

Affected Modules

RCHMGR    

Affected Publications

Summary Information

Status............................................ CLOSED PER
HIPER........................................... No
Component.................................. 5724H7206
Failing Module.......................... RCHMGR
Reported Release................... R600
Duplicate Of..............................




System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15Q","label":"APARs - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V6R0M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
11 December 2012