IBM Support

PQ97616: HD POINTER CHECKER ISSUES ABENDU3999 WHEN REQUIRED DATABASES ARENOT SPECIFIED.

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • In the HD Pointer Checker job, it is required that all logically
    related and index databases are specified in the PROCCTL data
    set. When this condition is not satisfied, HD Pointer Checker
    should end with a RC=04 or a RC=00 - however, HD Pointer Checker
    issues ABENDU3999 incorrectly.
    

Local fix

  • 
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IBM IMS High Performance Pointer Checker for *
    *                 z/OS Version 2 Release 1 (FMID=HPC2210)      *
    *                 users and                                    *
    *                 IMS High Performance Image Copy Version 3    *
    *                 Release 1 (FMID=H1J0310) and Version 3       *
    *                 Release 2 (FMID=H1J0320) users who invoke    *
    *                 the full-function database HASH check        *
    *                 function.                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: In the HD Pointer Checker job, it is    *
    *                      required that all logically related and *
    *                      index databases are specified in the    *
    *                      PROCCTL data set at once. When this     *
    *                      condition is not satisfied, HD Pointer  *
    *                      Checker should end with RC=04 or RC=00. *
    *                      However, HD Pointer Checker issues      *
    *                      ABENDU3999 incorrectly.                 *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    A database number(DB#) is assigned to all logically or
    index databases by the HD Pointer Checker.
    This error causes because HD Pointer Checker process the DB#
    incorectly, when some logically or index databases are not
    processed.
    
    The detailed conditions of this error is as follows:
    1. The databases are non-HALDB.
    2. Some logically related or index databases are not specified
       in the DATABASE statement in the PROCCTL data set.
    3. The DB# of the unspecified database is smaller than
       the DB# of the specified database.
    4. The specified database has pointers pointing to the
       unspecified database, and the target database having a
       smaller DB# than the specified database.
    
    When all of the following conditions are satisfied,
    HD Pointer Checker searches the internal control block by the
    DB# of unspecified database instead of the specified database,
    and gets ABENDU3999.
    

Problem conclusion

  • The module FABPHEVL is corrected not to use the unspecified DB#.
    

Temporary fix

  • 
    

Comments

  • 
    

APAR Information

  • APAR number

    PQ97616

  • Reported component name

    IMS POINTER CHE

  • Reported component ID

    5655E0900

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2004-11-24

  • Closed date

    2004-11-30

  • Last modified date

    2005-01-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ95570

Modules/Macros

  •    FABPHEVL
    

Fix information

  • Fixed component name

    IMS POINTER CHE

  • Fixed component ID

    5655E0900

Applicable component levels

  • R210 PSY UQ95570

       UP04/12/02 P F412

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89G","label":"IMS HP Pointer Checker"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210"}]

Document Information

Modified date:
03 April 2021