Error description

  • BTSARCN0 allows only RECFM=FB for SYSPRINT DD.
    If SYSPRINT DD is a VB file, BTSARCN0 issues message
    "BTSA1013E NO LOG DATASETS FOUND MATCHING SELECTION CRITERIA."
    BTS should allow RECFM=VB for SYSPRINT DD.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: BTS V3 Users with Playback                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: If SYSPRINT DD is RECFM=VB file,        *
    *                      BTSARCN0 puts the message "BTSA1013E    *
    *                      NO LOG DATASETS FOUND MATCHING SELECTIO *
    *                      CRITERIA."                              *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    If the NORECON control statement is specified to run BTSARCN0,
    the SYSPRINT file must be prepared with your own LIST.LOG
    results.
    BTSARCN0 could use SYSPRINT with DCB for this data set:
    RECFM=FB,LRECL=133. RECFM=VB was not allowed.
    If SYSPRINT DD that was prepared with the separated LIST.LOG
    is VB file, BTSARCN0 puts the message
    "BTSA1013E NO LOG DATASETS FOUND MATCHING SELECTION CRITERIA."
    

Problem conclusion

Temporary fix

Comments

  • BTSARCN0 is modified to allow RECFM=VB as SYSPRINT DD.
    
    The IMS BTS User's Guide and Reference ( SC18-7149-00 )
    will be updated with following changes:
    
    <E.1.4.1 Extraction of Log Data Set Names from RECON (BTSARCN0)>
    
    << Add after SLDS on LOGTYPE= >>
    
     - LOGS
       The primary log data sets will be used.
    
    << Add after PRISLD on LOGTYPE= >>
    
     - PRILOG
       The primary log data sets will be used.
    
    << Add after OLDSLD on LOGTYPE= >>
    
     - SECLOG
       The secondary log data sets will be used.
    
    
    << Add at last of the comment on SYSPRINT >>
    
    Only if you do use the NORECON control statement, you can
    specify RECFM=VB on the DCB for this data set.
    

APAR Information

  • APAR number

    PQ94051

  • Reported component name

    IMS BTS

  • Reported component ID

    5655A1400

  • Reported release

    310

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2004-09-10

  • Closed date

    2004-09-14

  • Last modified date

    2004-10-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ92849

Modules/Macros

  •    BTSARCN0
    

Publications Referenced
SC18714900    

Fix information

  • Fixed component name

    IMS BTS

  • Fixed component ID

    5655A1400

Applicable component levels

  • R310 PSY UQ92849

       UP04/09/15 P F409

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.