A fix is available
APAR status
Closed as program error.
Error description
ABEND0C4 IN BPLBTCH9 (OR BPLBTCH8 OR BPLBTCH7 OR BPLBTCH6 OR BPLBTCH5) AT OFFSET +322 WHEN A BATCH JOB HAS A MISSING OR INVALID DBD. POSSIBLE ABEND0C4 DURING BPLTRACE TASK TERMINATION IF THE TARGET ADDRESS SPACE ENDS BEFORE THE IMS OSAM TRACE IS STOPPED. IMS V9.1 COMPATABILITY CORRECTION.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS Buffer Pool Analyzer users. * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 in BPLBTCH9 at offset +322 * * when a batch job has a missing or * * invalid DBD. * **************************************************************** * RECOMMENDATION: * **************************************************************** ABEND0C4 in BPLBTCH9(or BPLBTCH8 or BPLBTCH7 or BPLBTCH6 or BPLBTCH5) at offset +322 when a batch job has a missing or invalid DBD. Possible ABEND0C4 during BPLTRACE Task Termination if the target address space ends before the IMS OSAM Trace is stopped. IMS 9.1 compatability correction.
Problem conclusion
Validate DMB addresses to prevent use of a DMB address of 0. Perform additional verification that batch job is still present before turning off the OSAM trace bit in the SCD. Correct which bit is tested for a batch job's use of DBRC.
Temporary fix
Comments
APAR Information
APAR number
PQ92266
Reported component name
IMS BUFFER POOL
Reported component ID
5697H7700
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2004-08-02
Closed date
2004-08-05
Last modified date
2004-09-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ91435
Modules/Macros
BPLBTCH5 BPLBTCH6 BPLBTCH7 BPLBTCH8 BPLBTCH9 BPLFMOD BPLTRACE
Fix information
Fixed component name
IMS BUFFER POOL
Fixed component ID
5697H7700
Applicable component levels
R110 PSY UQ91435
UP04/08/06 P F408
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.