IBM Support

PQ90929: FIX SOME DEFECTIVE LOGIC IN DEDB RANDOMIZER FOR BMP WITH PARDLI=1

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If a DEDB SR is called in a BMP with PARDLI=1 specified, the
    control region gets a user abend 070 (ABENDU070).
    < Additional symptom keywords >  2004/07/07 TT
     IMS control region failed with abend0c4 at IEAVETCL +03A6 or
    abend070 - 10 RC10 in IEAVETCL when a vendor s/w FILE-AID
    FILEAID accessed a DEDB through SRG / SDO generated randomizer.
    This happens after IMS APAR PQ65385 (V7), PQ74231 (V8) or
    PQ86621 (V9) has been installed.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS Sequential Randomizer       *
    *                 Generator for OS/390 Release 1               *
    *                 (FMID=H1J1110) who are using a DEDB          *
    *                 randomizer that was generated by SRG.        *
    ****************************************************************
    * PROBLEM DESCRIPTION: After IMS maintenance PQ65385 (for V7), *
    *                      PQ74231 (for V8) or PQ86621 (for V9)    *
    *                      has been applied, IMS control region    *
    *                      gets a system abend 070 (ABEND070) when *
    *                      a DEDB SR generated by SRG is called in *
    *                      a BMP with PARDLI=1.                    *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    After IMS maintenance PQ65385 (for V7), PQ74231 (for V8) or
    PQ86621 (for V9) has been applied, IMS control region fails
    with ABEND0C4 at IEAVETCL +03A6 or ABEND070 - 10 RC10 in
    IEAVETCL when a DEDB SR generated by SRG is called in a BMP with
    PARDLI=1 specified. This problem occurs also if a BMP
    environment with PARDLI=1 is set up implicitly in a program and
    a DEDB for which an SR generated by SRG is accessed in it. Such
    programs include IBM File Manager for z/OS Version 3
    (PID: 5655-J48) IMS Feature and Compuware File-AID for IMS, an
    OEM software.
    

Problem conclusion

  • The FABOF macro has been modified so that it will issue ISWITCH
    macro with STACK/UNSTACK option when a DEDB SR is running in IMS
    Version 7 or later.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PQ90929

  • Reported component name

    IMS SEQ RANDOMI

  • Reported component ID

    5655E1100

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2004-07-02

  • Closed date

    2004-07-21

  • Last modified date

    2004-08-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ90845

Modules/Macros

  •    FABOF
    

Fix information

  • Fixed component name

    IMS SEQ RANDOMI

  • Fixed component ID

    5655E1100

Applicable component levels

  • R110 PSY UQ90845

       UP04/07/23 P F407

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSEQ76","label":"IBM IMS Sequential Randomizer Generator for OS\/390"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
25 March 2021