Error description
-
ABENDS0C4 could occur producing the 'DBD Summary Report'.
Local fix
Problem summary
-
**************************************************************** * USERS AFFECTED: All users of IBM IMS High Performance Load * * for OS/390 Release 1 (FMID=H1IM110) who are * * using IPR Reload utility of IMS Parallel * * Reorganization for z/OS Version 2 Release 1 * * (FMID=H25N210). * **************************************************************** * PROBLEM DESCRIPTION: IPR Reload utility can receive * * ABENDS0C4-04 in CSECT HPSRRDBD. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** IPR Reload utility can receive ABENDS0C4-04 in CSECT HPSRRDBD while producing "DBD Summary report" for a HALDB DBD that contains no Logical Child Table. The CSECT is added by APAR PQ77101.
Problem conclusion
-
CSECT HPSRRDBD has been modified so that it will correctly count the number of logical child pointers for each segment in a HALDB DBD.
Temporary fix
Comments
APAR Information
-
APAR number
PQ84901
-
Reported component name
IMS HIGH PERF L
-
Reported component ID
5655E0700
-
Reported release
110
-
Status
CLOSED PER
-
PE
NoPE
-
HIPER
NoHIPER
-
Special Attention
NoSpecatt / Xsystem
-
Submitted date
2004-02-18
-
Closed date
2004-02-26
-
Last modified date
2004-03-03
-
APAR is sysrouted FROM one or more of the following:
-
APAR is sysrouted TO one or more of the following:
UQ85578
Modules/Macros
-
HPSRRDBD
Fix information
-
Fixed component name
IMS HIGH PERF L
-
Fixed component ID
5655E0700
Applicable component levels
-
R110 PSY UQ85578
UP04/03/01 P F402
Fix is available
-
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89F","label":"IMS HP Load"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"110"}]
Document Information
Modified date:
03 April 2021