A fix is available
APAR status
Closed as program error.
Error description
Batch Collect process fails for a DBD that has a DYNLIB member, but the phyiscal data set no longer exists. This DBD was handled by ISPF Collect with an appropriate message. The Batch Collect process terminated immediately without a message.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: ALL DATABASE CONTROL SUITE USERS. * **************************************************************** * PROBLEM DESCRIPTION: FOR DATABASE CONTROL SUITE R2.2.0 USERS * * 1.) ARITHMETIC FAILURE IN IDLRLSTC REXX * * *************************************** * * FOR DATABASE CONTROL SUITE R3.1.0 USERS * * 1.) BATCH COLLECT FAILS WHEN A DBD IN * * DYNLIB HAS NO PHYSICAL DATASET. * * 2.) ARITHMETIC FAILURE IN IDLRLSTC REXX * * 3.) PARALLEL REORG JCL FAILURE OCCURS * * WHEN NO FULL FUNCTION DATABASE * * PRE-REORG ALLOCATION OF DATASET * * FOR DFSURCDS IS REQUIRED. * **************************************************************** * RECOMMENDATION: * **************************************************************** FOR DATABASE CONTROL SUITE R2.2.0 USERS 1.) NEED TO INCREASE NUMERIC DIGIT PRECISION IN IDLRLSTC REXX. *************************************** FOR DATABASE CONTROL SUITE R3.1.0 USERS 1.) BATCH COLLECT FAILS WHEN A DBD IN DYNLIB HAS NO PHYSICAL DATASET. 2.) NEED TO INCREASE NUMERIC DIGIT PRECISION IN IDLRLSTC REXX. 3.) PARALLEL REORG JCL FAILURE OCCURS WHEN NO FULL FUNCTION DATABASE PRE-REORG ALLOCATION OF DATASET FOR DFSURCDS IS REQUIRED.
Problem conclusion
FOR DATABASE CONTROL SUITE USERS OF R2.2.0 1.) INCREASE NUMERIC DIGITS PRECISION IN IDLRLSTC REXX. FOR DATABASE CONTROL SUITE USERS OF R3.1.0 1.) INCREASE NUMERIC DIGITS PRECISION. IN IDLRLSTC REXX. 2.) ISSUE ERROR MSG IN BATCH COLLECT FOR MISSING DATABASE DATASETS. 3.) REMOVE DFSURCDS DD FROM IMS PARALLEL REORG JOB STEP FOR FULL FUNCTION DATABASE REORG. 4.) CORRECT VARIABLE USAGE FOR IMS RELEASE VALUE ON PANELS IDLSOPT0 AND IDLSOPT1 FOR IC2 UTILITY GROUP NAME OPTION VALIDATION TEST.
Temporary fix
Comments
APAR Information
APAR number
PQ84259
Reported component name
IMS DB CNTL SUI
Reported component ID
5655F7600
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2004-02-05
Closed date
2004-02-11
Last modified date
2004-03-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ85040 UQ85041
Modules/Macros
IDLC0001 IDLIPR01 IDLRLSTC IDLRLST2 IDLRREX1 IDLRREX2 IDLSOPT0 IDLSOPT1
Fix information
Fixed component name
IMS DB CNTL SUI
Fixed component ID
5655F7600
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX88W","label":"IMS Database Control Suite"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310"}]
Document Information
Modified date: