IBM Support

PQ83725: ATTEMPTING TO FOLLOW THE LP POINTER GET ABEND 0C1

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When navigating a DBORG: HIDAM   DSORG: OSAM database:
    1. Select the LP pointer and press ENTER
    2. Panel FABZP02 appears with the correct details, press ENTER
    3. Abend - SYSTEM COMPLETION CODE=0C1  REASON CODE=00000001
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IMS Database Repair Facility -Version 1      *
    *                 Release 1                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: 0C1 after hitting enter on panel=       *
    *                      fabzp02. This 0C1 is preceeded by       *
    *                      "IEC130I SYSPRINT DD STATEMENT MISSING  *
    *                                                              *
    *                                                              *
    *                                                              *
    *                                                              *
    *                                                              *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This problem occurred on P02, after
    following a LP pointer in panel=
    fabzps2. But, it could occur for any
    occurence of fabzp02.
    

Problem conclusion

  • The source of the 0C1 is the failed
    allocation of SYSPRINT file, evidenced
    by "IEC130I SYSPRINT DD STATEMENT
    MISSING". SYSPRINT in this case
    represents dataset=
    userid.prodid.dbdmap(xdbd). This is a
    temporary dataset used by DBRF. The fix
    allocates this as a larger dataset,
    and only puts 1 member,'xdbd', in it.
    also, prior to doing the ALLOC, we
    strip the dataset name of leading and
    trailing blanks,which also cause
    alloc failures.
    This fix also changes the message
    displayed in upper right corner of
    some panels that display filtered
    tables. Example,such a panel was
    displaying "row 1 of 17",when there
    were only 5 rows showing. The new
    message just says "5 Rows" in this
    example.
    
    
    
    
    110Y
    FABZDBMP
    FABZMAIN
    FABZMAP
    FABZPROC
    FABZPRO2
    FABZP02
    FABZ07
    

Temporary fix

Comments

APAR Information

  • APAR number

    PQ83725

  • Reported component name

    IMS DATABASE RE

  • Reported component ID

    5655E0300

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2004-01-23

  • Closed date

    2004-02-04

  • Last modified date

    2004-03-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ84802

Modules/Macros

  • FABZDBMP FABZMAIN FABZMAP  FABZPROC FABZPRO2
    FABZP02  FABZ07
    

Fix information

  • Fixed component name

    IMS DATABASE RE

  • Fixed component ID

    5655E0300

Applicable component levels

  • R110 PSY UQ84802

       UP04/02/05 P F402