IBM Support

PQ83454: LOCEPAX=YES NOT SPECIFIED AS IEFZB505 OPTION. GARBAGE CLEANUP NOT DONE IN THE PARAMETER AREA FOR SWQMPA BEFORE CALLING SWAREQ.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • LOCEPAX=YES not specified as IEFZB505 option. Garbage cleanup
    not done in the parameter area for SWQMPA before calling SWAREQ.
    .
    The potential cause of the error is:
     - LOCEPAX=YES is not specified as IEFZB505 option
     - The garbage is not cleaned up in parameter area that is for
       SWAQMPA before calling SWAREQ
    This APAR is a forward fit of ICE V2 PQ83347.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 3 users (FMID=H1J0310)               *
    ****************************************************************
    * PROBLEM DESCRIPTION: HPIC V3 Recovery Function gets ABEND    *
    *                      S0C4 ( ABEND0C4 ) when checking the     *
    *                      number of space extension for OSAM      *
    *                      database data set.                      *
    *                                                              *
    *                      This is the foreword fit APAR of        *
    *                      PQ83347 for IMS Image Copy Extensions   *
    *                      for z/OS Version 2.                     *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    HPIC V3 Recovery function gets ABEND S0C4 ( ABEND0C4 ) when
    checking the number of space extension for OSAM database
    data set.
    Because the Recovery function does not uses LOCEPAX=YES option
    of IEFZB505 macro that defines EPA parameter area for issuing
    SWAREQ macro with Read Locate mode. As the result of that
    garbage is set in SWQMPA (SWA control blocks) and SWAREQ
    process fails.
    

Problem conclusion

  • FABJCRC1, FABJDOPN and FABUFIG1 macro have been modified that:
     - LOCEPAX=YES option of IEFZB505 macro is defined.
     - Parameter area of SWAREQ is cleared with correct parameter
       length.
    FABJFIG1 has been reassembled.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PQ83454

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2004-01-20

  • Closed date

    2004-01-27

  • Last modified date

    2004-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UQ84481

Modules/Macros

  • FABJCRC1 FABJDOPN FABJFIG1 FABJMSGC FABUFIG1
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R310 PSY UQ84481

       UP04/01/30 P F401

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"310","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: