A fix is available
APAR status
Closed as program error.
Error description
LOCEPAX=YES not specified as IEFZB505 option. Garbage cleanup not done in the parameter area for SWQMPA before calling SWAREQ. . The potential cause of the error is: - LOCEPAX=YES is not specified as IEFZB505 option - The garbage is not cleaned up in parameter area that is for SWAQMPA before calling SWAREQ This APAR is a forward fit of ICE V2 PQ83347.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IMS High Performance Image Copy for z/OS * * Version 3 users (FMID=H1J0310) * **************************************************************** * PROBLEM DESCRIPTION: HPIC V3 Recovery Function gets ABEND * * S0C4 ( ABEND0C4 ) when checking the * * number of space extension for OSAM * * database data set. * * * * This is the foreword fit APAR of * * PQ83347 for IMS Image Copy Extensions * * for z/OS Version 2. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** HPIC V3 Recovery function gets ABEND S0C4 ( ABEND0C4 ) when checking the number of space extension for OSAM database data set. Because the Recovery function does not uses LOCEPAX=YES option of IEFZB505 macro that defines EPA parameter area for issuing SWAREQ macro with Read Locate mode. As the result of that garbage is set in SWQMPA (SWA control blocks) and SWAREQ process fails.
Problem conclusion
FABJCRC1, FABJDOPN and FABUFIG1 macro have been modified that: - LOCEPAX=YES option of IEFZB505 macro is defined. - Parameter area of SWAREQ is cleared with correct parameter length. FABJFIG1 has been reassembled.
Temporary fix
Comments
APAR Information
APAR number
PQ83454
Reported component name
IMS HP IMAGE CO
Reported component ID
5655K9600
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2004-01-20
Closed date
2004-01-27
Last modified date
2004-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ84481
Modules/Macros
FABJCRC1 FABJDOPN FABJFIG1 FABJMSGC FABUFIG1
Fix information
Fixed component name
IMS HP IMAGE CO
Fixed component ID
5655K9600
Applicable component levels
R310 PSY UQ84481
UP04/01/30 P F401
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"310","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: