IEC142I 113-0C received in FABHPSFM running Parallel Scan Facility when the dataset spans more than 5 volumes. FABHPSFM is not coping with change of the Allocation Retrieval Area (mapped by the IHAARA macro) by OS.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS High Performance Unload for * * OS/390 Release 1 (FMID=H1IN110) who are * * using the Parallel Scan Facility of FABHFSU. * **************************************************************** * PROBLEM DESCRIPTION: The message IEC142I 113-0C received in * * FABHPSFM when the OSAM database data * * set spans more than 5 volumes. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** The message IEC142I 113-0C received in FABHPSFM if both of the following conditions are met: - the OSAM database data set spans more than 5 volumes. - running under OS/390 V2R10 or later release. It is because it moved beyond necessity and following DCB Exit List has been broken, since OS/390 V2R10 to Allocation Retrieval Area ( ARA: mapped by the IHAARA macro ) was extended, although FABHPSFM is moving the volume name of the 6th henceforth to internal area from ARA.
Problem conclusion
The module FABHPSFM has been modified to move the volume name from ARA correctly.
Temporary fix
Comments
APAR Information
APAR number
PQ81449
Reported component name
IMS HIGHPERF UN
Reported component ID
5655E0600
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2003-11-26
Closed date
2003-12-05
Last modified date
2004-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UQ82901
Modules/Macros
FABHPSFM
Fix information
Fixed component name
IMS HIGHPERF UN
Fixed component ID
5655E0600
Applicable component levels
R110 PSY UQ82901
UP03/12/10 P F312
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSCX89K","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"110"}]
Document Information
Modified date:
20 October 2020